Spatio-temporal variations of indoor air quality in a university library.

The present study aims to assess the air quality status in the central library of Indian Institute of Technology Roorkee, India. Pollutants concentrations (i.e. PM10, PM2.5, PM1 and TVOC) and comfort parameters i.e. CO2, temperature and relative humidity were monitored across all floors of the libra...

Descripción completa

Detalles Bibliográficos
Publicado en:International Journal of Environmental Health Research Vol. 31; no. 5; pp. 475 - 491
Autores principales: Sahu, Veerendra, Gurjar, Bhola Ram
Formato: pictorial research tables/charts Journal Article
Publicado: Taylor & Francis Ltd Oct2021
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=150565381&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 150565381
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09603123
        57L
      jtl: International Journal of Environmental Health Research
      issn: 09603123
      maglogo: Y
    pubinfo:
      dt: Oct2021
      vid: 31
      iid: 5
      pid: 377
      pub: Taylor & Francis Ltd
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        150565381
        150565381
        150565381
        10.1080/09603123.2019.1668916
        150565381
      ppf: 475
      ppct: 16
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Spatio-temporal variations of indoor air quality in a university library.
      aug:
        au:
          Sahu, Veerendra
          Gurjar, Bhola Ram
        affil: Department of Civil Engineering, Indian Institute of Technology, Roorkee, India
      sug:
        subj:
          Air Pollution, Indoor Evaluation
          Libraries, Academic India
          India
          Particulate Matter
          Organic Chemicals
          Carbon Dioxide
          Humidity
          Environmental Pollutants
          Temperature
          World Health Organization
      ab: The present study aims to assess the air quality status in the central library of Indian Institute of Technology Roorkee, India. Pollutants concentrations (i.e. PM10, PM2.5, PM1 and TVOC) and comfort parameters i.e. CO2, temperature and relative humidity were monitored across all floors of the library. Air quality was found to vary significantly (P < 0.05) among the different floors of the library. The average concentration of PM10, PM2.5 and PM1 was found to be highest at the first floor. On the other hand, the highest concentration of TVOC (51.7 ± 30 ppb) and CO2 (838.4 ± 99 ppm) was observed at the ground floor. Pollutant concentration was higher in the morning hours. The indoor pollutants were found positively correlated with each other except relative humidity. Indoor to outdoor ratio for PM1, TVOC and CO2 was found to be greater than 1, which indicate a substantial contribution from indoor sources. Exceedance of WHO guidelines was observed for the daily average PM2.5 concentration. Abbreviation: IAQ: indoor air quality; ASHRAE: American Society of Heating, Refrigerating, and Air-Conditioning Engineers; WHO: World Health Organization; PM: particulate matter; VOC: volatile organic carbon; CO2: carbon dioxide; TVOC: Total volatile organic compound; RH: relative humidity; HVAC: heating ventilation and air-conditioning; PID: Photo Ionization Detector; PTFE: Polytetrafluoroethylene; NDIR: Non-dispersive infra-red.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N