Evaluation of Corrosion Behavior by Measuring Passivation Current Density of Dental Implant Coated with Bioceramic Materials.

Background. This paper reports the corrosion behavior of uncoated commercially pure titanium and Ti-6Al-4V samples and these coated with hydroxyapatite, partial stabilized zirconia (PSZ), and the mixture of partial stabilized zirconia and hydroxyl-apatite by measuring passivation current density and...

Descripción completa

Detalles Bibliográficos
Publicado en:BioMed Research International pp. 1 - 7
Autores principales: Hameed, Hanan Ali, Hasan, Haider Ali, Alam, Mohammad Khursheed
Formato: research tables/charts Journal Article
Publicado: Wiley-Blackwell 6/11/2021
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=150853325&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 150853325
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        23146133
        FT2T
      jtl: BioMed Research International
      issn: 23146133
      maglogo: N
    pubinfo:
      dt: 6/11/2021
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        150853325
        150853325
        150853325
        10.1155/2021/9934073
        150853325
      ppf: 1
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Evaluation of Corrosion Behavior by Measuring Passivation Current Density of Dental Implant Coated with Bioceramic Materials.
      aug:
        au:
          Hameed, Hanan Ali
          Hasan, Haider Ali
          Alam, Mohammad Khursheed
        affil: Prosthodontic Department, College of Dentistry, University of Babylon, Iraq
      sug:
        subj:
          Dental Implants
          Dental Materials
          Titanium
          Hydroxyapatites
          Alloys
          Metals
      ab: Background. This paper reports the corrosion behavior of uncoated commercially pure titanium and Ti-6Al-4V samples and these coated with hydroxyapatite, partial stabilized zirconia (PSZ), and the mixture of partial stabilized zirconia and hydroxyl-apatite by measuring passivation current density and see if there are any differences between them using electrochemical polarization tests in 37°C Hank's solution. Materials and Methods. The electrophoretic deposition method (EPD) was elected to keep the coating materials which are HA, PSZ, and the mixture of 50% HA and 50% PSZ on Cp Ti and Ti-6Al-4V alloy samples. The electrochemical corrosion test was achieved by exposing the coated and uncoated samples to Hank's solution which prepared in the laboratory and measuring the polarization potential, passivation current density, and the open circuit potential for all samples. Results. The results indicated that the passivation current density for all Cp Ti and Ti-6Al-4V alloy groups that coated with HA, PSZ, and with mixture of 50/50 HA and PSZ was less than uncoated groups. There are no significant differences between all Cp Ti groups when compared with all Ti-6Al-4 V alloy groups. The open circuit potential (OCP) for both Cp Ti and Ti -6Al -4V samples was in the following sequence PSZ > HA > mixture of HA and PSZ > uncoated. Conclusions. Coating significantly decreased the passivation current density of Cp Ti and Ti-6Al-4V alloy.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N