Comparing asynchrony in two noninvasive ventilators.

Objectives: Noninvasive ventilation (NIV) is commonly used in respiratory failure as an alternative to more invasive tracheal intubation. A major challenge of NIV is synchronization between the patient's spontaneous breathing efforts and the support of the ventilator. Design: We compared simulator-v...

Descripción completa

Detalles Bibliográficos
Publicado en:Critical Care & Shock Vol. 24; no. 5; pp. 218 - 231
Autores principales: Freebairn, Ross C., Waldmann, Andreas D., Remus, Christian, Pedro, Michael J.
Formato: research tables/charts Journal Article
Publicado: Critical Care & Shock Journal 2021
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=152665703&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 152665703
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        14107767
        6CKO
      jtl: Critical Care & Shock
      issn: 14107767
      maglogo: N
    pubinfo:
      dt: 2021
      vid: 24
      iid: 5
      pid: 45459
      pub: Critical Care & Shock Journal
      place: Houston, Texas
    artinfo:
      ui:
        152665703
        152665703
        152665703
        152665703
      ppf: 218
      ppct: 13
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Comparing asynchrony in two noninvasive ventilators.
      aug:
        au:
          Freebairn, Ross C.
          Waldmann, Andreas D.
          Remus, Christian
          Pedro, Michael J.
        affil: Otago Medical School, University of Otago, Dunedin, New Zealand
      sug:
        subj:
          Ventilators, Mechanical Evaluation
          Respiration, Artificial
          Simulations
          Human
          Equipment Failure
          Waveforms Evaluation
          Pressure (Physiology) Evaluation
          Tidal Volume
          Descriptive Statistics
          Comfort
          Work of Breathing
          Positive Pressure Ventilation Evaluation
          Insufflation
      ab: Objectives: Noninvasive ventilation (NIV) is commonly used in respiratory failure as an alternative to more invasive tracheal intubation. A major challenge of NIV is synchronization between the patient's spontaneous breathing efforts and the support of the ventilator. Design: We compared simulator-ventilator synchrony characteristics of two ventilators during noninvasive ventilation, using an adult lung simulator under three leak configurations. Setting: Bench test with lung simulator. Patients and participants: Active Servo Lung with the bellavista 1000 NIV (bellavista NIV) and Respironics V60 (V60). Interventions: Three configurations simulating different levels of unintended leak were tested for each ventilator: No Leak, Continuous Leak, and Inspiratory Leak. The recorded pressure and volume waveforms were analyzed to quantify trigger delay, triggering pressure-time product (PTPtrig), pressure-time product at 300 ms (PTP300), insufflation time excess (TI,excess), and time required to reach 63.2% (Texp,63) and 95.0% Texp,95) of expired tidal volume (VTexp) for each ventilator in all three leak scenarios. Measurements and results: Trigger delays for the bellavista NIV were significantly lower for all three leak conditions (p<0.0001) and it responded faster to simulated muscle activity compared to the V60. Both the bellavista NIV and V60 experienced no auto-trigger or missed trigger events. The bellavista NIV reached target pressure values more quickly as indicated by significantly higher PTP300 for all three leak conditions (p<0.0001) and had significantly shorter TI,excess (p<0.0001). The bellavista NIV experienced no delayed cycling breaths while more than 25% of V60 breaths showed delayed cycling during inspiratory leak tests. Conclusions: The bellavista NIV showed significantly lower trigger delays for all three leak conditions, reached target pressure values more quickly (i.e., higher PTP300), and showed superior cycling performance (i.e., lower trigger delay) compared to the V60, which may improve patient-ventilator synchrony and patient comfort.