Micra‐AV leadless pacemaker and atrioventricular (dys)synchrony: A stepwise process.
Leadless pacemakers have become a major breakthrough in the management of bradyarrhythmia as an attractive alternative to the standard transvenous pacemakers, but safety and long‐term outcomes of the new Micra‐AV, which is capable guarantee atrioventricular (AV) synchrony, have been poorly described...
| Published in: | Pacing & Clinical Electrophysiology Vol. 44; no. 10; pp. 1738 - 1743 |
|---|---|
| Main Authors: | , , , , , , |
| Format: | case study diagnostic images pictorial tracings Journal Article |
| Published: |
Wiley-Blackwell
Oct2021
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=152842276&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 152842276 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 01478389 4F8 jtl: Pacing & Clinical Electrophysiology issn: 01478389 maglogo: Y pubinfo: dt: Oct2021 vid: 44 iid: 10 pid: 480 pub: Wiley-Blackwell place: Malden, Massachusetts artinfo: ui: 152842276 152385708 152842276 152842276 10.1111/pace.14352 152842276 ppf: 1738 ppct: 5 formats: fmt: – @attributes: type: T – @attributes: type: C – @attributes: type: P tig: atl: Micra‐AV leadless pacemaker and atrioventricular (dys)synchrony: A stepwise process. aug: au: Mitacchione, Gianfranco Schiavone, Marco Gasperetti, Alessio Ruggiero, Diego Denora, Marialessia Viecca, Maurizio Forleo, Giovanni Battista affil: Cardiology Unit, ASST‐Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy sug: subj: Pacemaker, Artificial Adverse Effects Cardiac Pacing, Artificial Methods Equipment Failure Cardiac Resynchronization Therapy Female Middle Age Electrocardiography, Ambulatory Electrocardiography Exercise Test Middle Aged: 45-64 years Female ab: Leadless pacemakers have become a major breakthrough in the management of bradyarrhythmia as an attractive alternative to the standard transvenous pacemakers, but safety and long‐term outcomes of the new Micra‐AV, which is capable guarantee atrioventricular (AV) synchrony, have been poorly described. Hence, we describe how we managed a 57‐year‐old patient who developed pacemaker syndrome due to significant Micra‐AV dyssynchrony. This case emphasizes how leadless pacemaker AV synchrony could be overestimated, thereby requiring a stepwise process leading to adequate device reprogramming. Holter‐ECG monitoring and exercise test resulted to be valuable tools for an early detection of inadequate AV synchrony, integrating and completing device reports. pubtype: Academic Journal doctype: case study diagnostic images pictorial tracings Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|