β Agonist Delivery by High-Flow Nasal Cannula During COPD Exacerbation.

BACKGROUND: Whereas high-flow nasal cannula (HFNC) oxygen therapy is increasingly used in patients with exacerbation of COPD, the effectiveness of β2 agonist nebulization through HFNC has been poorly assessed. We hypothesized that salbutamol vibrating-mesh nebulization through HFNC improves pulmonar...

Descripción completa

Detalles Bibliográficos
Publicado en:Respiratory Care Vol. 67; no. 1; pp. 9 - 16
Autores principales: Beuvon, Clément, Coudroy, Rémi, Bardin, Justine, Marjanovic, Nicolas, Rault, Christophe, Bironneau, Vanessa, Drouot, Xavier, Robert, René, Thille, Arnaud W., Frat, Jean-Pierre
Formato: research tables/charts Journal Article
Publicado: Mary Ann Liebert, Inc. Jan2022
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=154455487&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 154455487
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00201324
        4GG
      jtl: Respiratory Care
      issn: 00201324
      maglogo: N
    pubinfo:
      dt: Jan2022
      vid: 67
      iid: 1
      pid: 1365
      pub: Mary Ann Liebert, Inc.
      place: New Rochelle, New York
    artinfo:
      ui:
        154455487
        154455487
        154455487
        10.4187/respcare.09242
        154455487
      ppf: 9
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: β Agonist Delivery by High-Flow Nasal Cannula During COPD Exacerbation.
      aug:
        au:
          Beuvon, Clément
          Coudroy, Rémi
          Bardin, Justine
          Marjanovic, Nicolas
          Rault, Christophe
          Bironneau, Vanessa
          Drouot, Xavier
          Robert, René
          Thille, Arnaud W.
          Frat, Jean-Pierre
        affil: INSERM CIC-1402, ALIVE Research Group, University of Poitiers, Poitiers, France
      sug:
        subj:
          Pulmonary Disease, Chronic Obstructive Therapy
          Disease Exacerbation Therapy
          Albuterol Administration and Dosage
          Surgical Mesh
          Nebulizers and Vaporizers
          Nasal Cannula
          Oxygen Therapy Equipment and Supplies
          Respiratory Function Tests
          Human
          Physiological Studies
          Prospective Studies
          Crossover Design
          Intensive Care Units
          Spirometry
          Forced Expiratory Volume Physiology
          Diagnostic Imaging
          Glasgow Coma Scale
          Scales
          Dyspnea
          Software
          Peak Expiratory Flow Rate Evaluation
          Tidal Volume Evaluation
          Quantitative Studies
          Descriptive Statistics
          Comparative Studies
          T-Tests
          Data Analysis Software
          Sex Factors
          Age Factors
          Confidence Intervals
      ab: BACKGROUND: Whereas high-flow nasal cannula (HFNC) oxygen therapy is increasingly used in patients with exacerbation of COPD, the effectiveness of β2 agonist nebulization through HFNC has been poorly assessed. We hypothesized that salbutamol vibrating-mesh nebulization through HFNC improves pulmonary function tests in subjects with COPD. METHODS: We conducted a physiological crossover study including subjects admitted to the ICU for severe exacerbation of COPD. After subject improvement allowing a 3-h washout period without bronchodilator, pulmonary function tests were performed while breathing through HFNC alone and after salbutamol vibrating-mesh nebulization through HFNC. The primary end point consisted in the changes in FEV1 before and after salbutamol nebulization. Secondary end points included the changes in FVC, peak expiratory flow (PEF), airway resistance, and clinical parameters. RESULTS: Among the 15 subjects included, mean (SD) FEV1 significantly increased after salbutamol nebulization from 931 mL (383) to 1,019 (432), mean difference +87 mL (95% CI 30-145) (P 5 .006). Similarly, FVC and PEF significantly increased, +174 mL (95% CI 66-282) (P 5 .004) and +0.3 L/min (95% CI 0-0.6) (P 5 .037), respectively. Airway resistances and breathing frequency did not significantly differ, whereas heart rate significantly increased after nebulization. CONCLUSIONS: In subjects with severe exacerbation of COPD, salbutamol vibrating-mesh nebulization through HFNC induced a significant bronchodilator effect with volume and flow improvement.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N