Multilayer zirconia: Influence of positioning within blank and sintering conditions on the in vitro performance of 3-unit fixed partial dentures.

Multilayer zirconia blanks comprise material layers with different optical and mechanical properties. Whether positioning within the blank, as well as variation in the sintering procedure, will lead to restorations with different properties is unclear. The purpose of this in vitro study was to test...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Prosthetic Dentistry Vol. 127; no. 1; pp. 141 - 146
Autores principales: Rosentritt, Martin, Preis, Verena, Schmid, Alois, Strasser, Thomas
Formato: research Journal Article
Publicado: Elsevier B.V. Jan2022
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=154592465&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 154592465
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00223913
        1ZB
      jtl: Journal of Prosthetic Dentistry
      issn: 00223913
      maglogo: N
    pubinfo:
      dt: Jan2022
      vid: 127
      iid: 1
      pid: 467
      pub: Elsevier B.V.
      place: New York, New York
    artinfo:
      ui:
        154592465
        154592465
        154592465
        10.1016/j.prosdent.2020.11.009
        154592465
      ppf: 141
      ppct: 5
      formats:
      tig:
        atl: Multilayer zirconia: Influence of positioning within blank and sintering conditions on the in vitro performance of 3-unit fixed partial dentures.
      aug:
        au:
          Rosentritt, Martin
          Preis, Verena
          Schmid, Alois
          Strasser, Thomas
        affil: Professor, Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
      sug:
        subj:
          Denture, Partial, Fixed Methods
          Dental Restoration, Temporary Methods
          Metals, Heavy
          Dental Materials
          Materials Testing
          Human
          Molar
          In Vitro Studies
          Treatment Outcomes Evaluation
          Acrylic Resins
          Dental Prosthesis Design
          Models, Anatomic
          Dental Cements
          Dental Bonding
          Water
          Mechanics
          Tooth Fractures
          Prosthesis Failure
          One-Way Analysis of Variance
          Post Hoc Analysis
          Heat
      ab: Multilayer zirconia blanks comprise material layers with different optical and mechanical properties. Whether positioning within the blank, as well as variation in the sintering procedure, will lead to restorations with different properties is unclear. The purpose of this in vitro study was to test the influence of sintering procedures and positioning in a multilayer blank on the in vitro performance of 3-unit zirconia fixed partial dentures. Human molars were embedded in acrylic resin and prepared for 3-unit fixed partial dentures. Anatomic contour prostheses were milled from zirconia blanks (ZirCAD Prime 16 mm) in 3 different positions: above (cusp-top at the top of the blank), central (center of the prosthesis in the center of the blank), and bottom (margins at the lower edge of the blank). Sintering time (2:26, 4:25, 9:50 hours:minutes) was varied for the central and bottom prostheses. All prostheses were glazed and adhesively bonded. Thermocycling and mechanical loading was performed at 2×3000×5 °C/55 °C in distilled water for 1.2×106 cycles at a 50-N load. Then, fracture force was determined with a universal testing device by using central loading, a Ø12-mm steel ball, a 1-mm tin foil, and a rate of 1 mm/min. Failure was defined as 10% force drop or acoustic signal (crack). Statistical analysis was performed with 1-way ANOVA and Bonferroni correction (α=.05). All fixed partial dentures survived thermocycling and mechanical loading. Fracture forces varied between 1002 ±446 N (above; 9:50 hours) and 1760 ±607 N (central; 9:50 hours). The 1-way ANOVA revealed no statistically significant differences (P=.059) among the groups. Individual significant differences (P=.048) were found between prostheses from positions above, 9:50 hours, and central, 9:50 hours. For normal and long sintering times, fracture forces were highest in the central position. The sintering process and positioning of restorations within a multilayer zirconia blank have little effect on the mechanical properties of the prostheses.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N