Comparison of quantitative 3D magnetic resonance cholangiography measurements obtained using three different image acquisition methods.

Purpose: To compare quantitative biliary measurements obtained with three different magnetic resonance cholangiopancreatography (MRCP) acquisition methods. Methods: This retrospective study was IRB-approved. Patients with combinations of clinically indicated 3D FSE MRCP with sensitivity encoding (SE...

Descripción completa

Detalles Bibliográficos
Publicado en:Abdominal Radiology Vol. 47; no. 1; pp. 196 - 209
Autores principales: Mahalingam, Neeraja, Ralli, George P., Trout, Andrew T., Dillman, Jonathan R.
Formato: diagnostic images research tables/charts Journal Article
Publicado: Springer Nature Jan2022
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=154792888&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 154792888
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        2366004X
        JT14
      jtl: Abdominal Radiology
      issn: 2366004X
      maglogo: N
    pubinfo:
      dt: Jan2022
      vid: 47
      iid: 1
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        154792888
        153358756
        154792888
        154792888
        10.1007/s00261-021-03330-2
        154792888
      ppf: 196
      ppct: 13
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Comparison of quantitative 3D magnetic resonance cholangiography measurements obtained using three different image acquisition methods.
      aug:
        au:
          Mahalingam, Neeraja
          Ralli, George P.
          Trout, Andrew T.
          Dillman, Jonathan R.
        affil: Department of Radiology, Imaging Research Center, Cincinnati Children's Hospital Medical Center, 250 Albert Sabin Way, Cincinnati, OH, USA
      sug:
        subj:
          Imaging, Three-Dimensional Methods
          Magnetic Resonance Imaging Methods
          Cholangiography Methods
          Biliary Tract Anatomy and Histology
          Human
          Comparative Studies
          Retrospective Design
          Descriptive Statistics
          Algorithms
          Intraclass Correlation Coefficient
          Wilcoxon Signed Rank Test
          Quantitative Studies
      ab: Purpose: To compare quantitative biliary measurements obtained with three different magnetic resonance cholangiopancreatography (MRCP) acquisition methods. Methods: This retrospective study was IRB-approved. Patients with combinations of clinically indicated 3D FSE MRCP with sensitivity encoding (SENSE), 3D FSE SENSE MRCP with compressed sensing (CS-FSE; acceleration factor 8), and 3D gradient and spin-echo (GRASE) MRCP, acquired between October 2018 and March 2020, were included. The MRCP + Tuning Threshold algorithm (Perspectum Ltd., Oxford, UK) was used to segment 3D biliary models from MRCP data, with multiple metrics quantified from the models. Single measure, two-way, mixed-effects intra-class correlations, Bland–Altman analyses, and Wilcoxon signed-rank tests were used to compare quantitative measurements. Results: From 160 MRCP datasets (25 3D FSE, 67 3D CS-FSE, 68 3D GRASE) in 69 patients, 48 datasets (7 [28%] 3D FSE, 14 [21%] 3D CS-FSE, 27 [40%] 3D GRASE) failed post-processing due to motion artifacts. The remaining 112 MRCP datasets (18 3D FSE, 53 3D CS-FSE, 41 3D GRASE) from 60 patients were included in the analysis. There was good to excellent agreement between 3D FSE and 3D CS-FSE MRCP for diameter of the left and right hepatic ducts, biliary volume, number and length of ducts, and total length of dilations (ICC: 0.83–0.93). The only metrics that exhibited good agreement between 3D FSE and 3D GRASE MRCP were biliary volume (ICC: 0.75) and total number of dilations (ICC: 0.77). Conclusion: 3D CS-FSE MRCP produces comparable biliary diameter metrics and global duct quantification to 3D FSE MRCP at a significantly reduced acquisition time.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N