Tibial anterior compartment compressibility in healthy subject, measured using compression sonography.

Introduction: Compression sonography has been introduced for non-invasive measurement of compartment compressibility and possible diagnostic tool for acute or chronic compartment syndrome in studies using human cadavers and animal models. To date, standard values in healthy subjects are not yet defi...

Descripción completa

Detalles Bibliográficos
Publicado en:Injury Vol. 53; no. 2; pp. 719 - 724
Autores principales: Anwander, Helen, Büchel, Livia, Krause, Fabian, Siebenrock, Klaus, Schmid, Timo
Formato: research Journal Article
Publicado: Elsevier B.V. Feb2022
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=154972714&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 154972714
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00201383
        JGC
      jtl: Injury
      issn: 00201383
      maglogo: N
    pubinfo:
      dt: Feb2022
      vid: 53
      iid: 2
      pid: 467
      pub: Elsevier B.V.
      place: New York, New York
    artinfo:
      ui:
        154972714
        154972714
        NLM34963511
        154972714
        10.1016/j.injury.2021.12.014
        NLM34963511
        154972714
      ppf: 719
      ppct: 5
      formats:
      tig:
        atl: Tibial anterior compartment compressibility in healthy subject, measured using compression sonography.
      aug:
        au:
          Anwander, Helen
          Büchel, Livia
          Krause, Fabian
          Siebenrock, Klaus
          Schmid, Timo
        affil: Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Switzerland
      sug:
        subj:
          Tibia
          Observer Bias
          Ultrasonography
          Pressure
          Research Subjects
          Reproducibility of Results
          Animals
          Ferrans and Powers Quality of Life Index
          Human
      ab: Introduction: Compression sonography has been introduced for non-invasive measurement of compartment compressibility and possible diagnostic tool for acute or chronic compartment syndrome in studies using human cadavers and animal models. To date, standard values in healthy subjects are not yet defined. The aim was to define standard compartment compressibility values in healthy human subjects and to assess the reliability of this measurement method.Methods: In 60 healthy volunteers, using ultrasound, the diameter of the tibial anterior compartment was measured while applying no pressure, 10mbar and 80mbar of external pressure. A pressure manometer on the ultrasound head was used to monitor the externally applied pressure. Compartment compressibility ratio (R0-80, respectively R10-80) was calculated as following: The delta of the compartment diameter with high and low external pressure, divided through the diameter with low external pressure. In 10 volunteers, two examinators conducted each two measurements to assess the reliability.Results: Mean compartment compressibility ratio R10-80 was 15.9% ±3.6 (range: 7.2 - 22.2). Mean compartment compressibility ratio R0-80 was 18.2% ±5.0 (3.0 - 32.1). There was no significant correlation with lower leg circumference, height, weight, BMI, gender, hours of sport per week and type of sport (e.g. weightlifting/ cardio). For R10-80, intraobserver ICC 2.1 was 0.89 for an experienced observer and 0.79 for a non-experienced observer. Interobserver ICC 2.1 was 0.78. For R0-80, intraobserver ICC 2.1 was 0.71 for the experienced and 0.56 for the unexperienced observer. Interobserver ICC 2.1 was 0.59.Discussion: In healthy volunteers between 18 and 50 years of age, mean compartment compressibility ratio R10-80 was 15.9% ±3.6, independent of demographic factors and sport activity. Application of 10mbar instead of 0mbar increased image quality. Subsequently, R10-80 showed lower standard deviation and both higher intraobserver and interobserver reliability than R0-80. Using R10-80, this measurement method is reliable with very high intra- and interobserver correlation.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N