Design of non-equal-strut stent hoops for structural optimization of thoracic aortic stent-grafts.
Endovascular aortic aneurysm repair (EVAR) with stent-grafts is used widely for the treatment of thoracic aortic aneurysms (TAA). Inappropriate design of stent-grafts may lead to complications such as endoleak, stent-graft migration and new entries, causes of which may be inappropriate radial suppor...
| Published in: | Minimally Invasive Therapy & Allied Technologies Vol. 31; no. 1; pp. 58 - 72 |
|---|---|
| Main Authors: | , , , |
| Format: | pictorial research tables/charts Journal Article |
| Published: |
Taylor & Francis Ltd
Jan 2022
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=155084096&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 155084096 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 13645706 J4S jtl: Minimally Invasive Therapy & Allied Technologies issn: 13645706 maglogo: Y pubinfo: dt: Jan 2022 vid: 31 iid: 1 pid: 377 pub: Taylor & Francis Ltd place: Philadelphia, Pennsylvania artinfo: ui: 155084096 145590300 155084096 155084096 10.1080/13645706.2020.1745849 155084096 ppf: 58 ppct: 14 formats: fmt: – @attributes: type: T – @attributes: type: P tig: atl: Design of non-equal-strut stent hoops for structural optimization of thoracic aortic stent-grafts. aug: au: Yan, Shiju Song, Chengli Si, Yi Zhao, Yiwen affil: School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China sug: subj: Prosthesis Design Stents Blood Vessel Prosthesis Aortic Aneurysm, Thoracic Surgery Human Treatment Outcomes Endovascular Procedures Blood Vessel Prosthesis Equipment and Supplies ab: Endovascular aortic aneurysm repair (EVAR) with stent-grafts is used widely for the treatment of thoracic aortic aneurysms (TAA). Inappropriate design of stent-grafts may lead to complications such as endoleak, stent-graft migration and new entries, causes of which may be inappropriate radial support force or insufficient longitudinal flexibility of the stent-grafts. To improve the mechanical performance of the stent-grafts, a type of non-equal-strut stent hoops was proposed, and the influence of structural parameters on the mechanical performance was studied. Results of numerical simulation and physical experiments show that by using the proposed non-equal-strut stent hoops, radial support force and longitudinal flexibility of stent-grafts can be reconciled and balanced. Results of this study could be used to facilitate radial force control and longitudinal flexibility enhancement in the design of aortic stent-grafts. pubtype: Academic Journal doctype: pictorial research tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|