Effect of Ti-Base Abutment Gingival Height on Maintenance of Crestal Bone in Thick Biotype Patients: A Randomized Clinical Trial with 1-Year Follow-up.

Purpose: To determine the effect of 0.7- and 2.4-mm transmucosal abutment height titanium bases on the crestal bone stability and peri-implant soft tissue condition of bone-level implants with platform switching in patients with vertically thick soft tissues. Materials and Methods: Sixty bone-level...

Descripción completa

Detalles Bibliográficos
Publicado en:International Journal of Oral & Maxillofacial Implants Vol. 37; no. 2; pp. 320 - 328
Autores principales: Linkevicius, Tomas, Alkimavicius, Jonas, Linkevicius, Rokas, Gineviciute, Evelina, Linkeviciene, Laura
Formato: diagnostic images pictorial research tables/charts randomized controlled trial Journal Article
Publicado: Quintessence Publishing Company Inc. Mar/Apr2022
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Purpose: To determine the effect of 0.7- and 2.4-mm transmucosal abutment height titanium bases on the crestal bone stability and peri-implant soft tissue condition of bone-level implants with platform switching in patients with vertically thick soft tissues. Materials and Methods: Sixty bone-level platform-switched implants were placed in the molar and premolar regions of both arches in 60 patients. All epicrestally inserted nonsubmerged implants had a 4.1-mm diameter and, after osteointegration, were randomly allocated into two groups: (1) the short group, with a titanium base of 0.7-mm transmucosal abutment height, and (2) the high group with a 2.4-mm height. Monolithic zirconia restorations were fabricated for all implants. Parallel intraoral radiographs were obtained after the delivery of restorations (T1) and after 1 year (T2). Crestal bone levels and peri-implant soft tissue conditions were calculated for each implant. The significance level was set at α = .05. Results: After 1 year, 55 patients were evaluated, with a mean bone loss of 0.6 ± 0.51 mm (median: 0.71, range: 0 to 2.09 mm) in the short group (23 patients) and 0.45 ± 0.59 mm (median: 0.65, range: 0 to 2.12 mm) in the high group (22 patients), showing no significant difference between groups (P = .168). A significant increase in marginal bone height was noted between the T1 and T2 time points in the short and high (P = .029 and .001, respectively) groups. The peri-implant soft tissue health parameters did not show statistically significant differences. Conclusion: Crestal bone stability after 1 year of follow-up around epicrestally placed platform-switched implants is not influenced by transmucosal abutment height, if the vertical soft tissue thickness is ≥ 3 mm.