Manipulación digital de la presentación fetal + Sims materna hacia el dorso fetal en presentaciones occipitoposteriores persistentes.

Objective: To determine the efficacy of digital manipulation of the fetal presentation together with the Sims position towards the fetal dorsum in the rotation of the occiput posterior (OP) presentations to occiput anterior (OA). Subjects/material and method: Women in active labor, with at least 7 c...

Full description

Bibliographic Details
Published in:Matronas Profesion Vol. 23; no. 2; pp. 60 - 68
Main Author: Gil, Gloria M. Alcaide
Format: Article
Published: Ediciones Mayo 2022
Subjects:
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=157555546&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 157555546
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        15780740
        635D
      jtl: Matronas Profesion
      issn: 15780740
      maglogo: N
    pubinfo:
      dt: 2022
      vid: 23
      iid: 2
      pid: 30380
      pub: Ediciones Mayo
    artinfo:
      ui: 157555546
      ppf: 60
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
            size: 7.2MB
      tig:
        atl: Manipulación digital de la presentación fetal + Sims materna hacia el dorso fetal en presentaciones occipitoposteriores persistentes.
      aug:
        au: Gil, Gloria M. Alcaide
        affil: Matrona en paritorio. Hospital de Montilla. Córdoba
      su:
        Statistics
        Human research subjects
        Fetal version (Obstetrics)
        Research methodology
        Women
        Fisher exact test
        Mann Whitney U Test
        Informed consent (Medical law)
        Mathematical variables
        T-test (Statistics)
        Fetal presentation
        Parity (Obstetrics)
        Chi-squared test
        Descriptive statistics
        Statistical sampling
        Labor (Obstetrics)
        Apgar score
        Data analysis
        Odds ratio
        Longitudinal method
      sug:
        subj:
          Statistics
          Human research subjects
          Fetal version (Obstetrics)
          Research methodology
          Women
          Fisher exact test
          Mann Whitney U Test
          Informed consent (Medical law)
          Mathematical variables
          T-test (Statistics)
          Fetal presentation
          Parity (Obstetrics)
          Chi-squared test
          Descriptive statistics
          Statistical sampling
          Labor (Obstetrics)
          Apgar score
          Data analysis
          Odds ratio
          Longitudinal method
      keyword:
        fetal malposition
        fetal rotation
        Occiput posterior
        malposición fetal
        Occipitoposterior
        rotación fetal
      ab:
        Objective: To determine the efficacy of digital manipulation of the fetal presentation together with the Sims position towards the fetal dorsum in the rotation of the occiput posterior (OP) presentations to occiput anterior (OA). Subjects/material and method: Women in active labor, with at least 7 cm of dilation, ruptured bursa, OP presentation and signing consent. A quasi experimental, single-center, prospective and convenience sampling study was carried out. The variables were: parity, presentation, epidural, time in Sims, fetal presentation at the end of delivery, type of delivery, Apgar test and pH. For the analysis of the effectiveness of the intervention and the comparison of the characteristics, the chi-square or Fisher test was used; the Student's f test or the Mann-Whitney test was used for continuous variables according to whether or not they followed a normal distribution, and the Pearson correlation or Spearman's Rho was used to evaluate the association between continuous variables. The incident factors in the success of the intervention were analyzed using logistic linear regression, and the results were expressed in terms of odds ratio (OR). Results: With a sample of 30 women, fetuses rotated to occiput anterior (OA) in 83.3 % of cases and only 16.66 % they finished in occiput posterior (OP). Of the deliveries that rotated to OA, 84.00 % were eutocic. There were no cae-sarean sections in the OA termination group. The five deliveries that ended in OP were caesarean sections. There were no differences in terms of Apgar test or pH between both groups. Conclusions: In the study sample, the combined use of both techniques provides a high turnover rate from OP to OA, with the obstetrics and neonatal benefits that this entails, anda drastic reduction in caesarean sections.
        Objetivo: Conocer la eficacia de la manipulación digital de la presentación fetal junto a la posición de Sims materna hacia el dorso fetal en la rotación de las presentaciones occipitoposteriores (OP) a occipitoanteriores (OA). Sujetos/material y método: Gestantes a término en trabajo de parto, desde 7 cm de dilatación, amniorrexis, presentación OP en el parto (OPP) y firma de consentimiento. Se realizó un estudio cuasiexperimental, unicentro, prospectivo y de muestreo por conveniencia. Las variables fueron: paridad, presentación, epidural, tiempo en Sims, presentación a la finalización del parto, tipo de parto, test de Apgar y pH. Para el análisis de la efectividad de la intervención y de la comparativa de las características utilizamos la prueba de chi-cuadrado o Fisher; el test de la t de Student o de Mann-Whitney para las variables continuas, según siguiesen o no una distribución normal, y la correlación de Pearson o Rho de Spearman para evaluar la asociación entre variables continuas. Los factores incidentes en el éxito de la intervención se analizaron mediante regresión lineal logística y los resultados se expresaron en términos de odds ratio (OR). Resultados: Con una muestra de 30 mujeres, los resultados fueron de un 83,3 % de finalización del parto en OA y de un 16,66 % en OP. De los partos que rotaron a OA, el 84,00 % fueron eutócicos. No hubo cesáreas en el grupo de finalización en OA. Los 5 partos que finalizaron en OP fueron cesáreas. No hubo diferencias en cuanto al test de Apgar y el pH entre ambos grupos. Conclusiones: En la muestra del estudio, el uso combinado de ambas técnicas proporciona una elevada tasa de rotación de OPP a OA, con los beneficios obstétricos y neonatales que ello conlleva, y una reducción drástica de las cesáreas. ©2022 Ediciones Mayo, S.A. Todos los derechos reservados.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: Spanish
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Matronas Profesion is the property of Ediciones Mayo and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Matronas Profesion
      holder: Ediciones Mayo
      dt:
        @attributes:
          year: 2022
    holdings:
      @attributes:
        islocal: N