Comparison of spin-echo echo-planar imaging magnetic resonance elastography with gradient-recalled echo magnetic resonance elastography and their correlation with transient elastography.

PURPOSE This study aimed to assess the agreement between liver stiffness (LS) values obtained by the gradient-recalled echo (GRE) magnetic resonance elastography (MRE) and spin-echo echo-planar imaging (SE-EPI) MRE with those of transient elastography (TE), respectively. METHODS We retrospectively i...

Descripción completa

Detalles Bibliográficos
Publicado en:Diagnostic & Interventional Radiology Vol. 28; no. 4; pp. 294 - 301
Autores principales: Jin Woo Yoon, Eun Sun Lee, Hyun Jeong Park, Sung Bin Park, Young Youn Cho, Kannengiesser, Stephan, Joonho Hur, Yoon, Jin Woo, Lee, Eun Sun, Park, Hyun Jeong, Park, Sung Bin, Cho, Young Youn, Hur, Joonho
Formato: diagnostic images research tables/charts Journal Article
Publicado: Galenos Yayinevi Tic. LTD. STI Jul2022
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=158525447&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 158525447
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        13053825
        39NM
      jtl: Diagnostic & Interventional Radiology
      issn: 13053825
      maglogo: N
    pubinfo:
      dt: Jul2022
      vid: 28
      iid: 4
      pid: 28155
      pub: Galenos Yayinevi Tic. LTD. STI
    artinfo:
      ui:
        158525447
        158525447
        NLM35950274
        158525447
        10.5152/dir.2022.201014
        NLM35950274
        158525447
      ppf: 294
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Comparison of spin-echo echo-planar imaging magnetic resonance elastography with gradient-recalled echo magnetic resonance elastography and their correlation with transient elastography.
      aug:
        au:
          Jin Woo Yoon
          Eun Sun Lee
          Hyun Jeong Park
          Sung Bin Park
          Young Youn Cho
          Kannengiesser, Stephan
          Joonho Hur
          Yoon, Jin Woo
          Lee, Eun Sun
          Park, Hyun Jeong
          Park, Sung Bin
          Cho, Young Youn
          Hur, Joonho
        affil: Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Heukseok-ro, Dongjak-gu, Republic of Korea
      sug:
        subj:
          Ultrasonography Methods
          Magnetic Resonance Imaging Methods
          Liver Pathology
          Retrospective Design
          Liver Cirrhosis Pathology
          Liver
          Reproducibility of Results
          Liver Cirrhosis
      ab: PURPOSE This study aimed to assess the agreement between liver stiffness (LS) values obtained by the gradient-recalled echo (GRE) magnetic resonance elastography (MRE) and spin-echo echo-planar imaging (SE-EPI) MRE with those of transient elastography (TE), respectively. METHODS We retrospectively included 48 participants who underwent liver MRE with both GRE and SE-EPI sequences in the same session and also TE within 1 year. We obtained LS values for MRE by drawing free-hand region of interest, and TE was performed using a FibroScan device. We assessed the relationship between the mean LS values obtained by each MRE sequence and TE using the correlation coefficients and Bland-Altman plots, respectively. We also compared LS values and technical failure rates of measured values from MRE between SE-EPI and GRE sequences using the paired t-test and McNemar's test. The MRE failure was defined as the absence of pixel value with a confidence index above 95%. RESULTS The LS values from SE-EPI and GRE sequences strongly correlated with those from TE (GRE; r = 0.73, P < .001 vs. SE-EPI; r = 0.79, P < .001). In addition, the LS values from the 2 MRE sequences showed excellent relationship (intraclass correlation coefficient, 0.94 [0.89-0.97], P < .001). The LS values from SE-EPI and GRE MRE were not significantly different (4.14 kPa vs. 3.88 kPa, P = .19). Furthermore, the technical success rate of SE-EPI MRE was superior to that of GRE (100% vs. 83.8%, P = .031). CONCLUSION The measured LS values obtained using TE correlated strongly with those obtained using GRE and SE-EPI MRE techniques, even though SE-EPI-MRE resulted a higher technical success rate than GRE-MRE. Therefore, we believe that TE, GRE, and SE-EPI MR elastography techniques may complement each other according to the appropriate individual situation.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N