Evaluation and optimization of novel extraction algorithms for the automatic detection of atrial activations recorded within the pulmonary veins during atrial fibrillation.

Background and Objective: The automated detection of atrial activations (AAs) recorded from intracardiac electrograms (IEGMs) during atrial fibrillation (AF) is challenging considering their various amplitudes, morphologies and cycle length. Activation time estimation is further complicated by the c...

Descripción completa

Detalles Bibliográficos
Publicado en:BMC Medical Informatics & Decision Making Vol. 22; no. 1; pp. 1 - 14
Autores principales: Prudat, Yann, Luca, Adrian, Yazdani, Sasan, Derval, Nicolas, Jaïs, Pierre, Roten, Laurent, Berte, Benjamin, Pruvot, Etienne, Vesin, Jean-Marc, Pascale, Patrizio
Formato: research Journal Article
Publicado: BioMed Central 8/28/2022
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=158781595&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 158781595
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        14726947
        1CI0
      jtl: BMC Medical Informatics & Decision Making
      issn: 14726947
      maglogo: N
    pubinfo:
      dt: 8/28/2022
      vid: 22
      iid: 1
      pid: 24147
      pub: BioMed Central
    artinfo:
      ui:
        158781595
        158781595
        NLM36031620
        158781595
        10.1186/s12911-022-01969-5
        NLM36031620
        158781595
      ppf: 1
      ppct: 13
      formats:
      tig:
        atl: Evaluation and optimization of novel extraction algorithms for the automatic detection of atrial activations recorded within the pulmonary veins during atrial fibrillation.
      aug:
        au:
          Prudat, Yann
          Luca, Adrian
          Yazdani, Sasan
          Derval, Nicolas
          Jaïs, Pierre
          Roten, Laurent
          Berte, Benjamin
          Pruvot, Etienne
          Vesin, Jean-Marc
          Pascale, Patrizio
        affil: Applied Signal Processing Group, Swiss Federal Institute of Technology, Lausanne, Switzerland
      sug:
        subj:
          Atrial Fibrillation
          Pulmonary Veins
          Heart Function Tests
          Algorithms
          Short Portable Mental Status Questionnaire
          Clinical Assessment Tools
      ab: Background and Objective: The automated detection of atrial activations (AAs) recorded from intracardiac electrograms (IEGMs) during atrial fibrillation (AF) is challenging considering their various amplitudes, morphologies and cycle length. Activation time estimation is further complicated by the constant changes in the IEGM active zones in complex and/or fractionated signals. We propose a new method which provides reliable automatic extraction of intracardiac AAs recorded within the pulmonary veins during AF and an accurate estimation of their local activation times.Methods: First, two recently developed algorithms were evaluated and optimized on 118 recordings of pulmonary vein IEGM taken from 35 patients undergoing ablation of persistent AF. The adaptive mathematical morphology algorithm (AMM) uses an adaptive structuring element to extract AAs based on their morphological features. The relative-energy algorithm (Rel-En) uses short- and long-term energies to enhance and detect the AAs in the IEGM signals. Second, following the AA extraction, the signal amplitude was weighted using statistics of the AA sequences in order to reduce over- and undersensing of the algorithms. The detection capacity of our algorithms was compared with manually annotated activations and with two previously developed algorithms based on the Teager-Kaiser energy operator and the AF cycle length iteration, respectively. Finally, a method based on the barycenter was developed to reduce artificial variations in the activation annotations of complex IEGM signals.Results: The best detection was achieved using Rel-En, yielding a false negative rate of 0.76% and a false positive rate of only 0.12% (total error rate 0.88%) against expert annotation. The post-processing further reduced the total error rate of the Rel-En algorithm by 70% (yielding to a final total error rate of 0.28%).Conclusion: The proposed method shows reliable detection and robust temporal annotation of AAs recorded within pulmonary veins in AF. The method has low computational cost and high robustness for automatic detection of AAs, which makes it a suitable approach for online use in a procedural context.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N