A solution for co-frequency and low SNR problems in heart rate estimation based on photoplethysmography signals.

In order to realize high-accuracy heart rate (HR) estimation based on photoplethysmography (PPG) under the scenes of low signal-to-noise ratio (SNR) and co-frequency caused by motion artifacts (MAs), this paper presents a novel framework integrating two-stage variational mode decomposition (VMD) den...

Descripción completa

Detalles Bibliográficos
Publicado en:Medical & Biological Engineering & Computing Vol. 60; no. 12; pp. 3419 - 3434
Autores principales: Zhao, Jiaqi, Chen, Xiang, Zhang, Xu, Chen, Xun
Formato: Journal Article
Publicado: Springer Nature Dec2022
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=160112195&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 160112195
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01400118
        PO0
      jtl: Medical & Biological Engineering & Computing
      issn: 01400118
      maglogo: N
    pubinfo:
      dt: Dec2022
      vid: 60
      iid: 12
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        160112195
        160112195
        NLM36190610
        10.1007/s11517-022-02678-x
        NLM36190610
        160112195
      ppf: 3419
      ppct: 15
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: A solution for co-frequency and low SNR problems in heart rate estimation based on photoplethysmography signals.
      aug:
        au:
          Zhao, Jiaqi
          Chen, Xiang
          Zhang, Xu
          Chen, Xun
        affil: Dept Elect Sci & Technol, University of Science and Technology of China, 230027, Hefei, Anhui, China
      sug:
        subj:
          Plethysmography Methods
          Signal Processing, Computer Assisted
          Sensitivity and Specificity
          Heart Rate Physiology
          Artifacts
          Algorithms
          Short Portable Mental Status Questionnaire
          Scales
          Exercise of Self-Care Agency Scale
      ab: In order to realize high-accuracy heart rate (HR) estimation based on photoplethysmography (PPG) under the scenes of low signal-to-noise ratio (SNR) and co-frequency caused by motion artifacts (MAs), this paper presents a novel framework integrating two-stage variational mode decomposition (VMD) denoising method, noise compensation technology, and hidden Markov model (HMM)-based tracking algorithm. The two-stage VMD denoising method is designed to separate the HR signal from MA under low SNR scene. The noise compensation technology is applied to solve the problem of co-frequency. HMM-based HR tracking method is adopted to obtain the global optimization performance of HR estimation. The effectiveness and superiority of the proposed framework in solving problems of low SNR and co-frequency associated with motion artifacts have been verified by the HR estimation experiments carried out on three public high-SNR PPG databases (ISPC, BAMI I, BAMI II) and a self-built low-SNR database (WeData). Compared with the two classical frameworks namely joint sparse spectrum reconstruction (JOSS) and convolutional neural network-long short-term memory network (CNN-LSTM), the proposed framework obtains the lowest HR estimation errors (0.94 beats per minute (BPM) and 1.81 BPM respectively) on both BAMI 2 with the highest SNR (0.40 dB) and WeData with the lowest SNR (- 9.07 dB). For the low-SNR database Wedata, the average absolute error (AAE) decreases by more than 21 BPM. The research result of this study provides a solution for the realization of high-accuracy PPG-based HR estimation in exercise scenarios.