Reliability and validity of a novel instrument for the quantification of hand forces during a jar opening task.

• The intrarater reliability and ecological validity of a novel and true-to-form jar instrument was tested in women with hand osteoarthritis • Intrarater reliability of the jar instrument was good to excellent and participants reported the experience of using it to be highly representative of jar-op...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Hand Therapy Vol. 35; no. 3; pp. 488 - 501
Autores principales: McGee, Corey, Mathiowetz, Virgil
Formato: research Journal Article
Publicado: Elsevier B.V. Jul2022
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=161121886&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 161121886
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        08941130
        4C0
      jtl: Journal of Hand Therapy
      issn: 08941130
      maglogo: N
    pubinfo:
      dt: Jul2022
      vid: 35
      iid: 3
      pid: 82545
      pub: Elsevier B.V.
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        161121886
        161121886
        161121886
        10.1016/j.jht.2021.04.012
        161121886
      ppf: 488
      ppct: 13
      formats:
      tig:
        atl: Reliability and validity of a novel instrument for the quantification of hand forces during a jar opening task.
      aug:
        au:
          McGee, Corey
          Mathiowetz, Virgil
        affil: University of Minnesota, Program in Occupational Therapy, Minneapolis, MN, USA
      sug:
        subj:
          Reliability and Validity
          Instrument Validation
          Task Performance and Analysis
          Hand Physiology
          Grip Strength Evaluation
          Women's Health
          Osteoarthritis, Hand
          Hand Joints
          Human
          Torque
          Validation Studies
          Intrarater Reliability
          Adult
          Female
          Descriptive Statistics
          Intraclass Correlation Coefficient
          Goal-Setting
          Kinetics
          Adult: 19-44 years
          Female
      ab: • The intrarater reliability and ecological validity of a novel and true-to-form jar instrument was tested in women with hand osteoarthritis • Intrarater reliability of the jar instrument was good to excellent and participants reported the experience of using it to be highly representative of jar-opening at home. • The jar tool may be used in future study of the required hand kinetics for successful opening of a sealed jar and for testing of joint protection strategies in this population. Clinical Measurement Jar opening is a task that relies heavily on the ability to generate adequate hand forces and is often reported in the literature as being difficult for women with hand arthritis. Many have studied relationships between diminished grip/pinch strength and occupational performance but few have investigated how much hand force is necessary to successfully engage in manual tasks. Those who studied this have relied on approaches and tools which lack ecology. Additionally, few have instrumented daily objects to understand if joint protection techniques do, in fact, reduce the hand force generation when performing manual tasks. The objectives of this study were to one) determine the within session repeatability of a device used to quantify these forces and two) probe into the ecological validity of a novel device to be used in the future study of women with hand osteoarthritis to measure hand force requirements and study the impact of joint protection interventions on hand force profiles. A plastic jar was instrumented with a torque limiter, 6-axis load cell, and six force sensing resistors so as to capture the grip and compressive hand forces which act on a jar lid when opening a sealed jar. To assess intra-rater reliability of the tool and its testing procedures, 31 adult women with hand osteoarthritis were asked untwist the jar's lid so as to break its seal with each hand twice while stabilizing the base with the opposing hand. The agreement between trials of peak forces and torques from each hand was assessed through statistical approaches including Intraclass Correlation Coefficient, Standard Error of the Measurement, and Minimal Detectable Change. The jar's ecological validity was then assessed via survey. This instrument and methods yielded good to excellent repeatability across all force outputs. The majority of our subjects (87%) reported the jar to be similar to those used at home, 87% reported to use a similar jar 2-3 times/month or greater, and rated the importance of opening such a jar as being, on average, 8.7/10. The jar instrument appears to have high reliability and ecologic validity. It has the potential to reveal hand force requirements for a population known to have difficulties opening jars and understanding these force thresholds could help to inform therapy goal-setting. Beyond this, it has the potential to support the study of the hand forces used across various joint protection approaches so as to inform best "jar-opening" practices. This tool was designed to represent the qualities of a standard, large sealed jar while still housing sophisticated kinetic measurement capacities. Our findings support that we have presented a tool which can be used in future study within this population to better understand the hand kinetics associated with the highly problematic task of jar-opening and joint protection strategies intended to reduce hand loads.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N