calf – Software for CEST Analysis with Lorentzian Fitting.

Analysis of chemical exchange saturation transfer (CEST) MRI data requires sophisticated methods to obtain reliable results about metabolites in the tissue under study. CEST generates z-spectra with multiple components, each originating from individual molecular groups. The individual lines with Lor...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Medical Systems Vol. 47; no. 1; pp. 1 - 15
Autores principales: Wittsack, Hans-Jörg, Radke, Karl Ludger, Stabinska, Julia, Ljimani, Alexandra, Müller-Lutz, Anja
Formato: Journal Article
Publicado: Springer Nature Dec2023
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=162691669&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 162691669
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01485598
        4N0
      jtl: Journal of Medical Systems
      issn: 01485598
      maglogo: N
    pubinfo:
      dt: Dec2023
      vid: 47
      iid: 1
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        162691669
        10.1007/s10916-023-01931-6
        162691669
      ppf: 1
      ppct: 14
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: calf – Software for CEST Analysis with Lorentzian Fitting.
      aug:
        au:
          Wittsack, Hans-Jörg
          Radke, Karl Ludger
          Stabinska, Julia
          Ljimani, Alexandra
          Müller-Lutz, Anja
        affil: Medical Faculty, Department of Diagnostic and Interventional Radiology, University Dusseldorf, D-40225, Dusseldorf, Germany
      sug:
      ab: Analysis of chemical exchange saturation transfer (CEST) MRI data requires sophisticated methods to obtain reliable results about metabolites in the tissue under study. CEST generates z-spectra with multiple components, each originating from individual molecular groups. The individual lines with Lorentzian line shape are mostly overlapping and disturbed by various effects. We present an elaborate method based on an adaptive nonlinear least squares algorithm that provides robust quantification of z-spectra and incorporates prior knowledge in the fitting process. To disseminate CEST to the research community, we developed software as part of this study that runs on the Microsoft Windows operating system and will be made freely available to the community. Special attention has been paid to establish a low entrance threshold and high usability, so that even less experienced users can successfully analyze CEST data.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N