A novel method of measuring proptosis with computed tomography.

Background: Computed tomography (CT) can avoid interference factors and has been imported into some software to measure proptosis clinically as the golden standard. Purpose: To establish a new method for semi-automatically measuring the proptosis on CT and evaluate its accuracy and reproducibility....

Descripción completa

Detalles Bibliográficos
Publicado en:Acta Radiologica Vol. 64; no. 9; pp. 2603 - 2611
Autores principales: Sun, Rou, Yin, Ziqing, Li, Lunhao, Zhou, Huifang, Song, Xuefei, Li, Yinwei
Formato: Journal Article
Publicado: Sage Publications Inc. Sep2023
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=171923794&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 171923794
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        02841851
        1XG
      jtl: Acta Radiologica
      issn: 02841851
      maglogo: Y
    pubinfo:
      dt: Sep2023
      vid: 64
      iid: 9
      pid: 344
      pub: Sage Publications Inc.
      place: Thousand Oaks, California
    artinfo:
      ui:
        171923794
        167347122
        10.1177/02841851231187859
        171923794
      ppf: 2603
      ppct: 8
      formats:
      tig:
        atl: A novel method of measuring proptosis with computed tomography.
      aug:
        au:
          Sun, Rou
          Yin, Ziqing
          Li, Lunhao
          Zhou, Huifang
          Song, Xuefei
          Li, Yinwei
        affil: Department of Ophthalmology, 56695Ninth People's Hospital, 56694Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
      sug:
      ab: Background: Computed tomography (CT) can avoid interference factors and has been imported into some software to measure proptosis clinically as the golden standard. Purpose: To establish a new method for semi-automatically measuring the proptosis on CT and evaluate its accuracy and reproducibility. Material and Methods: A total of 50 orbital CT images were collected of healthy individuals, 25 patients with Graves ophthalmopathy (GO), and 25 patients with orbital fracture (OF). A new image processing software, MedrawHDC, was developed to semi-automatically measure the proptosis (MedrawHDC method). The classic radiological (CR) method (measuring proptosis with the software called Mimics) and MedrawHDC method were applied in all three groups (measured by observer S). Hertel's exophthalmometer (HE) method was also applied in the GO group. Moreover, two other observers were asked to measure the proptosis using MedrawHDC, to evaluate its reproducibility. Results: The MedrawHDC method was highly consistent with the CR method in measuring proptosis (normal group: intraclass correlation coefficient [ICC] = 0.989; GO group: ICC = 0.979; OF group: ICC = 0.979). In the GO group, the value of proptosis measured by two radiological methods were consistent with that measured by the HE method (CR method: ICC = 0.703; MedrawHDC method: ICC = 0.697). Bland–Altman plots showed similar results. The measurements obtained by three observers were highly reproducible (ICC = 0.995). Conclusion: The newly established MedrawHDC method, with high accessibility, convenience, and repeatability, is reliable in assessing proptosis. It shows high potential for wide application, having clinical value for scientific evaluation of proptosis.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N