HCformer: Hybrid CNN-Transformer for LDCT Image Denoising.

Low-dose computed tomography (LDCT) is an effective way to reduce radiation exposure for patients. However, it will increase the noise of reconstructed CT images and affect the precision of clinical diagnosis. The majority of the current deep learning-based denoising methods are built on convolution...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Digital Imaging Vol. 36; no. 5; pp. 2290 - 2306
Autores principales: Yuan, Jinli, Zhou, Feng, Guo, Zhitao, Li, Xiaozeng, Yu, Hengyong
Formato: diagnostic images equations & formulas research tables/charts Journal Article
Publicado: Springer Nature Oct2023
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=171950855&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 171950855
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        08971889
        DOQ
      jtl: Journal of Digital Imaging
      issn: 08971889
      maglogo: N
    pubinfo:
      dt: Oct2023
      vid: 36
      iid: 5
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        171950855
        171950855
        171950855
        10.1007/s10278-023-00842-9
        171950855
      ppf: 2290
      ppct: 16
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: HCformer: Hybrid CNN-Transformer for LDCT Image Denoising.
      aug:
        au:
          Yuan, Jinli
          Zhou, Feng
          Guo, Zhitao
          Li, Xiaozeng
          Yu, Hengyong
        affil: https://ror.org/018hded08 The School of Electronic and Information Engineering, Hebei University of Technology, 300401, Tianjin, China
      sug:
        subj:
          Tomography, X-Ray Computed Adverse Effects
          Radiation Injuries Prevention and Control
          Radiation Dosage
          Radiographic Image Enhancement
          Image Processing, Computer Assisted
          Deep Learning
          Neural Networks (Computer)
          Human
          Experimental Studies
          Algorithms
          Comparative Studies
          Image Interpretation, Computer Assisted
          Ablation Techniques
      ab: Low-dose computed tomography (LDCT) is an effective way to reduce radiation exposure for patients. However, it will increase the noise of reconstructed CT images and affect the precision of clinical diagnosis. The majority of the current deep learning-based denoising methods are built on convolutional neural networks (CNNs), which concentrate on local information and have little capacity for multiple structures modeling. Transformer structures are capable of computing each pixel's response on a global scale, but their extensive computation requirements prevent them from being widely used in medical image processing. To reduce the impact of LDCT scans on patients, this paper aims to develop an image post-processing method by combining CNN and Transformer structures. This method can obtain a high-quality images from LDCT. A hybrid CNN-Transformer (HCformer) codec network model is proposed for LDCT image denoising. A neighborhood feature enhancement (NEF) module is designed to introduce the local information into the Transformer's operation, and the representation of adjacent pixel information in the LDCT image denoising task is increased. The shifting window method is utilized to lower the computational complexity of the network model and overcome the problems that come with computing the MSA (Multi-head self-attention) process in a fixed window. Meanwhile, W/SW-MSA (Windows/Shifted window Multi-head self-attention) is alternately used in two layers of the Transformer to gain the information interaction between various Transformer layers. This approach can successfully decrease the Transformer's overall computational cost. The AAPM 2016 LDCT grand challenge dataset is employed for ablation and comparison experiments to demonstrate the viability of the proposed LDCT denoising method. Per the experimental findings, HCformer can increase the image quality metrics SSIM, HuRMSE and FSIM from 0.8017, 34.1898, and 0.6885 to 0.8507, 17.7213, and 0.7247, respectively. Additionally, the proposed HCformer algorithm will preserves image details while it reduces noise. In this paper, an HCformer structure is proposed based on deep learning and evaluated by using the AAPM LDCT dataset. Both the qualitative and quantitative comparison results confirm that the proposed HCformer outperforms other methods. The contribution of each component of the HCformer is also confirmed by the ablation experiments. HCformer can combine the advantages of CNN and Transformer, and it has great potential for LDCT image denoising and other tasks.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        equations & formulas
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N