Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents.

Introduction: Scarce evidence is available about the minimum number of valid days wearing the activPAL3 to obtain a precise estimate of sedentary behaviour (SB) and awake-time movement behaviours (ATMB) in nursing home (NH) residents. The study aimed to determine the minimum number of valid days req...

Full description

Bibliographic Details
Published in:European Review of Aging & Physical Activity Vol. 20; no. 1; pp. 1 - 18
Main Authors: Farrés-Godayol, Pau, Ruiz-Díaz, Miguel Ángel, Dall, Philippa, Skelton, Dawn A., Minobes-Molina, Eduard, Jerez-Roig, Javier, Giné-Garriga, Maria
Format: Article
Published: BioMed Central 10/7/2023
Subjects:
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ssf&AN=172841881&site=ehost-live
header:
  @attributes:
    shortDbName: ssf
    uiTerm: 172841881
    longDbName: Social Sciences Full Text (H.W. Wilson)
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        18137253
        3RAQ
      jtl: European Review of Aging & Physical Activity
      issn: 18137253
      maglogo: N
    pubinfo:
      dt: 10/7/2023
      vid: 20
      iid: 1
      pid: 24147
      pub: BioMed Central
    artinfo:
      ui:
        172841881
        10.1186/s11556-023-00329-0
      ppf: 1
      ppct: 17
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
              size: 1.1MB
      tig:
        atl: Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents.
      aug:
        au:
          Farrés-Godayol, Pau
          Ruiz-Díaz, Miguel Ángel
          Dall, Philippa
          Skelton, Dawn A.
          Minobes-Molina, Eduard
          Jerez-Roig, Javier
          Giné-Garriga, Maria
        affil:
          https://ror.org/006zjws59 Research group on Methodology, Methods, Models and Outcomes of Health and Social Sciences, Faculty of Health Sciences and Welfare, Centre for Health and Social Care Research (CESS), University of Vic-Central University of Catalonia (UVic-UCC), C. Sagrada Família, 7, 08500, Vic, Spain
          Institute for Research and Innovation in Life Sciences and Health in Central Catalonia (IRIS-CC), Vic, Spain
          https://ror.org/01cby8j38 Department of Social Psychology and Methodology, Psychology Faculty, Universidad Autónoma de Madrid, Madrid, Spain
          https://ror.org/03dvm1235 Research Centre for Health (ReaCH), School of Health and Life Sciences, Glasgow Caledonian University, Glasgow, UK
          https://ror.org/04p9k2z50 Blanquerna Faculty of Psychology, Education and Sport Sciences, Ramon Llull University, Barcelona, Spain
          https://ror.org/04p9k2z50 Blanquerna Faculty of Health Sciences, Ramon Llull University, Barcelona, Spain
      su:
        Nursing home residents
        Cronbach's alpha
        Intraclass correlation
        Physical mobility
        Sedentary behavior
      sug:
        subj:
          Nursing home residents
          Cronbach's alpha
          Intraclass correlation
          Physical mobility
          Sedentary behavior
      keyword:
        activPAL3
        Minimum wear time duration
        Older adults
        Sedentary behaviour
        activPAL3
        Minimum wear time duration
        Older adults
        Sedentary behaviour
      ab: Introduction: Scarce evidence is available about the minimum number of valid days wearing the activPAL3 to obtain a precise estimate of sedentary behaviour (SB) and awake-time movement behaviours (ATMB) in nursing home (NH) residents. The study aimed to determine the minimum number of valid days required for accurately estimate SB and ATMB using the activPAL3 device in NH residents. It also investigated how the starting point of a day (the 24-h period) impacted reliability. Methods: Participants wore an activPAL3 for 7 consecutive days. The data was classified in two-time blocks (00:00 Ante Meridiem (AM)—00:00 AM midnight vs 12:00 Post Meridiam (PM) -12:00 PM midday) and the sample was stratified into two groups according to their capacity to stand and walk, to examine if timing of sampling or physical functioning affected minimum wear time. SB, ATMB, sociodemographic, and health-related variables were collected. Sensitivity of the time-blocks were tested through the dispersion frequencies and differences between blocks through Kolmogorov–Smirnov test for normality; parametric variables through two-related means T-test and Wilcoxon test for non-parametric data. Reliability was assessed with the Cronbach's Alpha and the intra-class correlation coefficient (ICC), using a one-factor model estimating the reliability for each measurement day loading in the same latent factor. Results: Ninety-five NH residents (81.1% women; age = 85.8 ± 7.2 years) were included. The midnight block had higher reliability, sensitivity and no statistically significant differences between days were found. At least three consecutive days of monitoring were necessary to achieve a reliability of ICC ≥ 0.8 for those NH residents able to stand and walk and six days for those unable. Conclusions: NH residents who are able to stand and walk require a minimum of three consecutive days wearing the device, while those who are unable require at least six days due to their highly homogenous daily routines and sensitivity to PA events. Regardless of the activPAL3 recording start time, data processing should reference the midnight time block.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: English
    refInfo:
    copyright:
      @attributes:
        flag: N
    holdings:
      @attributes:
        islocal: N