The Repeatability of Axial Length Measurements Using a Scheimpflug-based System.

Purpose: To assess the repeatability of Pentacam AXL as a Scheimpflug-based system or measuring axial length according to the age, sex, lens type, axial length value, and type of cataract. Methods: The present study was conducted using multistage cluster sampling in Tehran, Iran. Ocular biometry was...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Ophthalmic & Vision Research Vol. 18; no. 4; pp. 396 - 405
Autores principales: Sardari, Sara, Khabazkhoob, Mehdi, Jafarzadehpur, Ebrahim, Fotouhi, Akbar
Formato: research tables/charts Journal Article
Publicado: Knowledge E DMCC Oct-Dec2023
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=174336314&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 174336314
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        20082010
        AY5S
      jtl: Journal of Ophthalmic & Vision Research
      issn: 20082010
      maglogo: N
    pubinfo:
      dt: Oct-Dec2023
      vid: 18
      iid: 4
      pid: 35682
      pub: Knowledge E DMCC
    artinfo:
      ui:
        174336314
        174336314
        174336314
        10.18502/jovr.v18i4.14551
        174336314
      ppf: 396
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: The Repeatability of Axial Length Measurements Using a Scheimpflug-based System.
      aug:
        au:
          Sardari, Sara
          Khabazkhoob, Mehdi
          Jafarzadehpur, Ebrahim
          Fotouhi, Akbar
        affil: Research and Technology Deputy, Tehran University of Medical Sciences, Tehran, Iran
      sug:
        subj:
          Eye Physiology
          Body Weights and Measures
          Human
          Iran
          Multi-Stage Cluster
          Biometrics
      ab: Purpose: To assess the repeatability of Pentacam AXL as a Scheimpflug-based system or measuring axial length according to the age, sex, lens type, axial length value, and type of cataract. Methods: The present study was conducted using multistage cluster sampling in Tehran, Iran. Ocular biometry was performed, using the Pentacam AXL, by an experienced optometrist on all the participants. The axial length (AL) measurements were taken thrice, with a gap of 10 minutes. To evaluate the repeatability, the intraclass correlation coefficient (ICC) and the repeatability coefficient (RC) were calculated. To determine the significant difference in the repeatability index among study variables, the tolerance index (TI) was calculated. Results: In this report, 897 eyes of 677 individuals aged between 20 and 91 years (mean ±SD: 64.90 ±13.62 years) were reported. The ICC of the axial length measurements was 0.981 for all cases. Based on the within-subject standard deviation, the RC was 0.401. The ICC was 0.976 and 0.985 in men and women, respectively. The TI showed better RC of measurements among females. The ICC decreased from 0.999 in participants under 40 years to 0.973 in individuals over 60 years of age. The TI showed a decrease in RC with advancing age. The RC was worse in eyes with nuclear cataracts; the RC was also worse in the first quartile of the signal-to-noise ratio (SNR) compared to the other SNR quartiles. Conclusion: The Scheimpflug-based system Pentacam AXL had high repeatability in measuring axial length. Some variables such as male gender, older age, and nuclear cataract were associated with reduced repeatability of the measurements. A higher SNR was associated with better repeatability of the axial length measurements.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N