A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty.

Background and purpose -- The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been publi...

Descripción completa

Detalles Bibliográficos
Publicado en:Acta Orthopaedica Vol. 94; pp. 555 - 560
Autores principales: HURRY, Jennifer K., SPURWAY, Alan J., LAENDE, Elise K., REHAN, Saad, ASTEPHEN WILSON, Janie L., DUNBAR, Michael J., EL-HAWARY, Ron
Formato: diagnostic images pictorial research tables/charts Journal Article
Publicado: Medical Journals Sweden AB 2023
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=174668840&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 174668840
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        17453674
        1BVL
      jtl: Acta Orthopaedica
      issn: 17453674
      maglogo: N
    pubinfo:
      dt: 2023
      vid: 94
      pid: 59195
      pub: Medical Journals Sweden AB
    artinfo:
      ui:
        174668840
        174668840
        174668840
        10.2340/17453674.2023.19669
        174668840
      ppf: 555
      ppct: 5
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty.
      aug:
        au:
          HURRY, Jennifer K.
          SPURWAY, Alan J.
          LAENDE, Elise K.
          REHAN, Saad
          ASTEPHEN WILSON, Janie L.
          DUNBAR, Michael J.
          EL-HAWARY, Ron
        affil: Department of Orthopaedic Surgery, IWK Health Centre, Halifax, Nova Scotia, Canada
      sug:
        subj:
          Knee Joint Radiography
          Radiography Equipment and Supplies
          Radiation Dosage
          Radiostereometric Analysis
          Arthroplasty, Replacement, Knee
          Human
          In Vivo Studies
          Male
          Female
          Aged
          Weight-Bearing
          Image Processing, Computer Assisted
          Technology, Medical
          Aged: 65+ years
          Male
          Female
      ab: Background and purpose -- The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been published for this type of imaging system, thus the goal of this study was to assess the precision of RSA in vivo utilizing a low radiation biplanar imager. Patients and methods -- At a mean of 5 years post-surgery (range 1.4-7.5 years), 15 total knee arthroplasty (TKA) participants (mean age 67 years at the time of imaging, 12 female, 3 male) with RSA markers implanted during index surgery were scanned twice at the same visit in the EOS imager. Precision of marker-based analysis was calculated by comparing the position of the implant relative to the underlying bone between the 2 examinations. Results -- The 95% limit of precision was 0.11, 0.04, and 0.15 mm along the x, y, and z axes, respectively and 0.15°, 0.20°, and 0.14° around the same axes. Conclusion -- This precision study has shown an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20°, well within published uniplanar values for conventional arthroplasty RSA, with the added benefit of weight-bearing imaging, a lower radiation dose, and without the need for a reference object during the scan.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N