A Prospective, Longitudinal Study Evaluating the Efficacy of an Automated Secretion Removal Technology.

BACKGROUND: Endotracheal suctioning causes discomfort, is associated with adverse effects, and is resource-demanding. An artificial secretion removal method, known as an automated cough, has been developed, which applies rapid, automated deflation, and inflation of the endotracheal tube cuff during...

Descripción completa

Detalles Bibliográficos
Publicado en:Respiratory Care Vol. 69; no. 8; pp. 931 - 937
Autores principales: Sinnige, Jante S., Karbing, Dan S., Valk, Christel M. A., Schultz, Marcus J., Rees, Stephen E., Paulus, Frederique
Formato: research tables/charts Journal Article
Publicado: Mary Ann Liebert, Inc. Aug2024
Acceso en línea:Ver este registro en EBSCOhost