Improved overall image quality in low-dose dual-energy computed tomography enterography using deep-learning image reconstruction.

Objective: To demonstrate the clinical advantages of a deep-learning image reconstruction (DLIR) in low-dose dual-energy computed tomography enterography (DECTE) by comparing images with standard-dose adaptive iterative reconstruction-Veo (ASIR-V) images. Methods: In this Institutional review board...

Descripción completa

Detalles Bibliográficos
Publicado en:Abdominal Radiology Vol. 49; no. 9; pp. 2979 - 2988
Autores principales: Lin, Xu, Gao, Yankun, Zhu, Chao, Song, Jian, Liu, Ling, Li, Jianying, Wu, Xingwang
Formato: Journal Article
Publicado: Springer Nature Sep2024
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=179144147&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 179144147
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        2366004X
        JT14
      jtl: Abdominal Radiology
      issn: 2366004X
      maglogo: N
    pubinfo:
      dt: Sep2024
      vid: 49
      iid: 9
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        179144147
        176002065
        10.1007/s00261-024-04221-y
        179144147
      ppf: 2979
      ppct: 9
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Improved overall image quality in low-dose dual-energy computed tomography enterography using deep-learning image reconstruction.
      aug:
        au:
          Lin, Xu
          Gao, Yankun
          Zhu, Chao
          Song, Jian
          Liu, Ling
          Li, Jianying
          Wu, Xingwang
        affil: https://ror.org/03t1yn780 Department of Radiology, The First Affiliated Hospital of Anhui Medical University, 230022, Hefei, Anhui, China
      sug:
      ab: Objective: To demonstrate the clinical advantages of a deep-learning image reconstruction (DLIR) in low-dose dual-energy computed tomography enterography (DECTE) by comparing images with standard-dose adaptive iterative reconstruction-Veo (ASIR-V) images. Methods: In this Institutional review board approved prospective study, 86 participants who underwent DECTE were enrolled. The early-enteric phase scan was performed using standard-dose (noise index: 8) and images were reconstructed at 5 mm and 1.25 mm slice thickness with ASIR-V at a level of 40% (ASIR-V40%). The late-enteric phase scan used low-dose (noise index: 12) and images were reconstructed at 1.25 mm slice thickness with ASIR-V40%, and DLIR at medium (DLIR-M) and high (DLIR-H). The 70 keV monochromatic images were used for image comparison and analysis. For objective assessment, image noise, artifact index, SNR and CNR were measured. For subjective assessment, subjective noise, image contrast, bowel wall sharpness, mesenteric vessel clarity, and small structure visibility were scored by two radiologists blindly. Radiation dose was compared between the early- and late-enteric phases. Results: Radiation dose was reduced by 50% in the late-enteric phase [(6.31 ± 1.67) mSv] compared with the early-enteric phase [(3.01 ± 1.09) mSv]. For the 1.25 mm images, DLIR-M and DLIR-H significantly improved both objective and subjective image quality compared to those with ASIR-V40%. The low-dose 1.25 mm DLIR-H images had similar image noise, SNR, CNR values as the standard-dose 5 mm ASIR-V40% images, but significantly higher scores in image contrast [5(5–5), P < 0.05], bowel wall sharpness [5(5–5), P < 0.05], mesenteric vessel clarity [5(5–5), P < 0.05] and small structure visibility [5(5–5), P < 0.05]. Conclusions: DLIR significantly reduces image noise at the same slice thickness, but significantly improves spatial resolution and lesion conspicuity with thinner slice thickness in DECTE, compared to conventional ASIR-V40% 5 mm images, all while providing 50% radiation dose reduction.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N