Assessing the criterion validity of the activPAL CREA v1.3 algorithm and ActiPASS 2023.12 software for detecting steps during a progressive treadmill-based laboratory protocol.

Thigh-worn accelerometry is commonly implemented to measure step cadence. The default activPAL CREA algorithm is a valid measure of cadence during walking, but its validity during running is unknown. The ActiPASS software is designed to analyse tri-axial accelerometry data from various brands. We te...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Sports Sciences Vol. 42; no. 20; pp. 1951 - 1959
Autores principales: Pellerine, Liam. P., Courish, Molly K., Petterson, Jennifer L., Shivgulam, Madeline E., Johansson, Peter J., Hettiarachchi, Pasan, Kimmerly, Derek S., O'Brien, Myles W.
Formato: research tables/charts Journal Article
Publicado: Taylor & Francis Ltd Oct2024
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=180889790&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 180889790
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        02640414
        5BV
      jtl: Journal of Sports Sciences
      issn: 02640414
      maglogo: Y
    pubinfo:
      dt: Oct2024
      vid: 42
      iid: 20
      pid: 377
      pub: Taylor & Francis Ltd
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        180889790
        180451967
        180889790
        180889790
        10.1080/02640414.2024.2419222
        180889790
      ppf: 1951
      ppct: 8
      formats:
      tig:
        atl: Assessing the criterion validity of the activPAL CREA v1.3 algorithm and ActiPASS 2023.12 software for detecting steps during a progressive treadmill-based laboratory protocol.
      aug:
        au:
          Pellerine, Liam. P.
          Courish, Molly K.
          Petterson, Jennifer L.
          Shivgulam, Madeline E.
          Johansson, Peter J.
          Hettiarachchi, Pasan
          Kimmerly, Derek S.
          O'Brien, Myles W.
        affil: Division of Kinesiology, Dalhousie University, Halifax, NS, Canada
      sug:
        subj:
          Algorithms
          Software
          Criterion-Related Validity
          Accelerometry
          Treadmills
          Step
          Monitoring, Physiologic
          Human
          Wearable Sensors
          Descriptive Statistics
          Data Analysis Software
          Male
          Female
          Adult
          Middle Age
          Protocols
          Linear Regression
          Confidence Intervals
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Male
          Female
      ab: Thigh-worn accelerometry is commonly implemented to measure step cadence. The default activPAL CREA algorithm is a valid measure of cadence during walking, but its validity during running is unknown. The ActiPASS software is designed to analyse tri-axial accelerometry data from various brands. We tested the validity of CREA v1.3 and ActiPASS 2023.12 to measure step cadence against manually-counted steps. Forty-five participants (26♀, 23.4 ± 4.6 years) completed 5 walking (6 min each, 2–4 mph) and 5 running treadmill (5–7 mph) stages (423 total stages completed). Based on equivalence testing, walking cadence (stages 1–5: 92–124 steps/min) from CREA was statistically equivalent (zone: <±2.2% of the manually-counted mean) to manual counts (92–125 steps/min). However, CREA underpredicted cadence during running stages (stages 6–10: 143–135 steps/min) by ~ 11–20 steps/min (p < 0.001). The ActiPASS-derived cadences were equivalent (zone: <±3.3%) to manual counts for all walking stages (99–127 steps/min) except Stage 1 (zone: ±10.5%). ActiPASS underpredicted cadences during running (stages 6–10: 137–153 steps/min) by ~ 10–16 steps/min (p < 0.001) compared to manual counts (stages 6–10: 154–164 steps/min). The CREA v1.3 algorithm is a valid measure of cadence during walking while ActiPASS 2023.12 is a valid measure of cadence during medium-fast walking. Further research is required to improve step cadence estimation across ambulation speeds.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N