Uniformity test in three-dimensional rotational angiography: Novel tools and methods for advanced performance evaluation.

American Association of Physicists in Medicine (AAPM) Task Group (TG) 238 provides guidance on quality control procedures to ensuring optimal three-dimensional rotational angiography (3DRA) image quality. The uniformity test outlined in this guideline utilizes a sampling method, which provide limite...

Descripción completa

Detalles Bibliográficos
Publicado en:Radiography Vol. 31; no. 1; pp. 146 - 152
Autores principales: Saraswati, H.M.G., Lubis, L.E.
Formato: research Journal Article
Publicado: W B Saunders Jan2025
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=182363841&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 182363841
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10788174
        DPD
      jtl: Radiography
      issn: 10788174
      maglogo: N
    pubinfo:
      dt: Jan2025
      vid: 31
      iid: 1
      pid: 1351
      pub: W B Saunders
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        182363841
        182363841
        182363841
        10.1016/j.radi.2024.10.030
        182363841
      ppf: 146
      ppct: 6
      formats:
      tig:
        atl: Uniformity test in three-dimensional rotational angiography: Novel tools and methods for advanced performance evaluation.
      aug:
        au:
          Saraswati, H.M.G.
          Lubis, L.E.
        affil: Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Kampus UI Depok 16424, Indonesia
      sug:
        subj:
          Imaging, Three-Dimensional Evaluation
          Angiography Evaluation
          Image Processing, Computer Assisted
          Software Design
          Human
          Sensitivity and Specificity
          Quality Control (Technology)
          Image Interpretation, Computer Assisted
      ab: American Association of Physicists in Medicine (AAPM) Task Group (TG) 238 provides guidance on quality control procedures to ensuring optimal three-dimensional rotational angiography (3DRA) image quality. The uniformity test outlined in this guideline utilizes a sampling method, which provide limited information on image uniformity and has been found to be a sub-optimum predictor of image quality issues. Despite this limitation, numerous automated quality control software solutions for uniformity testing have been developed using the available method. Therefore, this study was aimed to propose new methods as well as to develop an in-house software to generate more comprehensive uniformity testing of 3DRA images. The uniformity evaluation techniques are adopted from both AAPM TG-238 guidelines and the European Reference Organisation for Quality Assured Breast Screening and Diagnostic Services (EUREF) guidelines. The parameters assessed included mean pixel value (MPV) and signal to noise ratio (SNR) following EUREF recommendations with limiting values adapted from AAPM TG-238. An in-house software was constructed to visually display non-uniformities and numerically by providing information on ROIs detected by each metric. With the introduction of new evaluation methods, the previously established limiting values could not be employed as a reference for determining image uniformity. Therefore, the selection of the optimal uniformity testing method will be based on its sensitivity in detecting and visually displaying non-uniformities. The new evaluation techniques provide a more comprehensive assessment of 3DRA image uniformity. However, further investigation is reserved to refine the limitation values used in determining the pass/fail criteria for the uniformity test. This in-house software enables visualization of uniformity within an image, aiding in the selection of the appropriate imaging mode based on clinical requirements.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N