The Effect of Decoupling Humidity Control on Aerosol Drug Delivery During HFNC for Infants.

Background: Aerosol therapy is commonly used during treatment with high-flow nasal cannula (HFNC) in the ICU. Heated humidification inside the HFNC tubing circuit leads to unwanted condensation, which may greatly limit the efficiency of drug delivery. In this study, we aimed to investigate whether a...

Descripción completa

Detalles Bibliográficos
Publicado en:Respiratory Care Vol. 70; no. 3; pp. 327 - 337
Autores principales: Zhang, Madeline X., Bem, Reinout A., Huijgen, Tom, Klein-Blommert, Rozalinde, Bonn, Daniel, van Rijn, Cees J.M.
Formato: research tables/charts Journal Article
Publicado: Mary Ann Liebert, Inc. Mar2025
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=183410952&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 183410952
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00201324
        4GG
      jtl: Respiratory Care
      issn: 00201324
      maglogo: N
    pubinfo:
      dt: Mar2025
      vid: 70
      iid: 3
      pid: 1365
      pub: Mary Ann Liebert, Inc.
      place: New Rochelle, New York
    artinfo:
      ui:
        183410952
        183410952
        183410952
        10.4187/respcare.12283
        183410952
      ppf: 327
      ppct: 10
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: The Effect of Decoupling Humidity Control on Aerosol Drug Delivery During HFNC for Infants.
      aug:
        au:
          Zhang, Madeline X.
          Bem, Reinout A.
          Huijgen, Tom
          Klein-Blommert, Rozalinde
          Bonn, Daniel
          van Rijn, Cees J.M.
        affil: Ms. Zhang and Drs. Bonn and van Rijn are affiliated with Institute of Physics, Van der Waals-Zeeman Institute, University of Amsterdam, Amsterdam, the Netherlands.
      sug:
        subj:
          Temperature Prevention and Control
          Humidity Prevention and Control
          Aerosols Administration and Dosage
          Nasal Cannula
          Administration, Inhalation
          Drug Delivery Systems
          Nebulizers and Vaporizers
          Oxygen Therapy Methods
          Human
          Funding Source
          Infant
          Fluorescent Dyes Administration and Dosage
          Spectrum Analysis
          Respiratory Airflow Evaluation
          Intubation, Intratracheal
          Critically Ill Patients
          Experimental Studies
          Intensive Care Units, Pediatric
          Academic Medical Centers
          Netherlands
          Equipment Design
          Temperature Evaluation
          Humidity Evaluation
          Aerosols Analysis
          T-Tests
          Two-Way Analysis of Variance
          Descriptive Statistics
          Data Analysis Software
          Expectorants Administration and Dosage
          Bronchodilator Agents Administration and Dosage
          Infant: 1-23 months
      ab: Background: Aerosol therapy is commonly used during treatment with high-flow nasal cannula (HFNC) in the ICU. Heated humidification inside the HFNC tubing circuit leads to unwanted condensation, which may greatly limit the efficiency of drug delivery. In this study, we aimed to investigate whether a novel humidification system, which decouples temperature and humidity control, can improve the delivered dose. Methods: In a bench study setup, fluorescein sodium solution was nebulized using a vibrating mesh nebulizer in an infant HFNC circuit to measure the delivered dose, with a conventional versus a decoupled humidifier. The deposition of fluorescein inside each breathing circuit component and a final collection filter at the end of the nasal cannula was collected and quantified with a UV-vis spectrometer. Droplet sizes at different sections of the breathing circuit were measured by laser diffraction. Three air flows, 5, 10, and 15 L/min; and 2 nebulizer positions, (1) at the humidifier and (2) after the inspiratory tube, were tested. Results: The delivered dose decreased with increasing flow for the conventional setup and was higher when the nebulizer was placed after the inspiratory tube. Turning off the conventional humidifier 10 min before and during nebulization did not improve the delivered dose. The decoupled humidifier achieved a significantly higher (P = .002) delivered dose than the conventional setup. The highest delivered dose obtained by the decoupled humidifier was 62.4% when the nebulizer was placed after the humidifier, while the highest dose obtained for the conventional humidifier was 36.3% by placing the nebulizer after the inspiratory tube. Conclusions: In this bench study, we found that the delivered dose for an infant HFNC nebulization setup could be improved significantly by decoupling temperature and humidity control inside the HFNC circuit, as it reduced drug deposition inside the breathing circuit.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N