Hasta Uyum Ölçeğinin Türkçe Geçerlilik ve Güvenilirliği.

Objectives: The aim of this study was to test the validity and reliability of the Turkish version of the Patient Compliance Scale to determine patients' compliance with treatment. Materials and Methods: The sample of the study consisted of 389 patients who applied to the outpatient clinic of a unive...

Full description

Bibliographic Details
Published in:Hacettepe University Faculty of Health Sciences Journal Vol. 12; no. 1; pp. 294 - 309
Main Author: Gözübüyük, Onur
Format: research tables/charts Journal Article
Published: Hacettepe University Faculty of Health Sciences Nursing Journal nis2025
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=185643879&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 185643879
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        25289918
        N2TI
      jtl: Hacettepe University Faculty of Health Sciences Journal
      issn: 25289918
      maglogo: N
    pubinfo:
      dt: nis2025
      vid: 12
      iid: 1
      pid: 50281
      pub: Hacettepe University Faculty of Health Sciences Nursing Journal
    artinfo:
      ui:
        185643879
        185643879
        185643879
        10.21020/husbfd.1476502
        185643879
      ppf: 294
      ppct: 15
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Hasta Uyum Ölçeğinin Türkçe Geçerlilik ve Güvenilirliği.
      aug:
        au: Gözübüyük, Onur
        affil: Bandırma Onyedi Eylül Üniversitesi, Sağlık Bilimleri Fakültesi, Sağlık Yönetimi Bölümü, Merkez Yerleşkesi, 10200, Bandırma/Balıkesir
      sug:
        subj:
          Instrument Validation
          Reliability and Validity Evaluation
          Scales
          Patient Compliance Evaluation
          Human
          Turkiye
          Female
          Male
          Validation Studies
          Outpatient Service
          Outpatients
          Convenience Sample
          Criterion-Related Validity
          Discriminant Validity
          Correlation Coefficient
          Item Analysis
          Coefficient alpha
          Internal Consistency
          Content Validity
          Construct Validity
          Factor Analysis
          Descriptive Statistics
          Female
          Male
      ab:
        Objectives: The aim of this study was to test the validity and reliability of the Turkish version of the Patient Compliance Scale to determine patients' compliance with treatment. Materials and Methods: The sample of the study consisted of 389 patients who applied to the outpatient clinic of a university hospital and were collected by the convenience sampling method. The personal information form and patient compliance scale were used as measurement tools. Confirmatory factor analysis, convergent validity and discriminant validity analyses, item-total correlation, and item analysis were performed, and the Cronbach Alpha reliability coefficient was used for internal consistency. Results: According to the findings of the researcher, the necessary compliance conditions for language equivalence, content validity, and construct validity of the patient compliance scale were met. The factor loadings of the scale ranged between 0.61-0.90. Cronbach's alpha value was determined to be 0.879. Conclusion: The results support that the patient compliance scale is a valid and reliable measurement tool. The scale was evaluated as a scale that can be applied to patients at both outpatient and clinical levels.
        Amaç: Bu çalışmanın amacı, hastaların tedaviye uyumunun belirlenmesine yönelik Hasta Uyum Ölçeğinin Türkçe Formunun geçerlilik ve güvenilirliğini test etmektir. Gereç ve Yöntem: Araştırmanın örneklemini bir üniversite hastanesinin polikliniğine başvuran ve kolayda örnekleme yöntemiyle toplanan 389 hasta oluşturmaktadır. Ölçme aracı olarak kişisel bilgi formu ve hasta uyum ölçeği kullanılmıştır. Ölçeğe doğrulayıcı faktör analizi, yakınsak geçerlilik ve ayırıcı geçerlilik analizleri, madde toplam korelasyonu ve madde analizi yapılmış, iç tutarlılık için Cronbach Alpha güvenilirlik katsayısından yararlanılmıştır. Bulgular: Çalışmacının bulgularına göre hasta uyum ölçeğinin dil eşdeğerliliği, kapsam geçerliliği ve yapı geçerliliği için gerekli uyum koşulları sağlanmaktadır. Ölçeğin faktör yükleri 0,61-0,90 arasında değişmektedir. Cronbach alfa değeri ise 0,879 olarak belirlenmiştir. Sonuç: Sonuçlar, hasta uyum ölçeğinin geçerli ve güvenilir bir ölçme aracı olduğunu desteklemektedir. Ölçek hem poliklinik hem de klinik düzeyde hastalara uygulanabilecek bir ölçek olarak değerlendirilmiştir.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: Turkish
    refInfo:
    holdings:
      @attributes:
        islocal: N