Diagnosis of moderate-to-severe hepatic steatosis using deep learning-based automated attenuation measurements on contrast-enhanced CT.

Purpose: To evaluate the utility of deep learning-based automated attenuation measurements on contrast-enhanced CT (CECT) for diagnosing moderate-to-severe hepatic steatosis (HS), using histology as reference standard. Methods: This retrospective study included 3,620 liver donors (2,393 men and 1,22...

Descripción completa

Detalles Bibliográficos
Publicado en:Abdominal Radiology Vol. 50; no. 9; pp. 4139 - 4148
Autores principales: Kim, Hae Young, Lee, Kyung Jin, Lee, Seung Soo, Choi, Se Jin, Kim, Dong Hwan, Heo, Subin, Jang, Hyeon Ji, Choi, Sang Hyun
Formato: Journal Article
Publicado: Springer Nature Sep2025
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=187189764&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 187189764
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        2366004X
        JT14
      jtl: Abdominal Radiology
      issn: 2366004X
      maglogo: N
    pubinfo:
      dt: Sep2025
      vid: 50
      iid: 9
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        187189764
        183747330
        10.1007/s00261-025-04872-5
        187189764
      ppf: 4139
      ppct: 9
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Diagnosis of moderate-to-severe hepatic steatosis using deep learning-based automated attenuation measurements on contrast-enhanced CT.
      aug:
        au:
          Kim, Hae Young
          Lee, Kyung Jin
          Lee, Seung Soo
          Choi, Se Jin
          Kim, Dong Hwan
          Heo, Subin
          Jang, Hyeon Ji
          Choi, Sang Hyun
        affil: https://ror.org/03s5q0090 Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
      sug:
      ab: Purpose: To evaluate the utility of deep learning-based automated attenuation measurements on contrast-enhanced CT (CECT) for diagnosing moderate-to-severe hepatic steatosis (HS), using histology as reference standard. Methods: This retrospective study included 3,620 liver donors (2,393 men and 1,227 women; mean age, 31.7 ± 9.4 years), divided into the development (n = 2,714) and test (n = 906) cohorts. Attenuation values of the liver and spleen on CECT were measured both manually and using a deep learning algorithm (before and after radiologists' correction of segmentation errors). Performance of: (1) liver attenuation and (2) liver–spleen attenuation difference for diagnosing moderate-to-severe HS (> 33%) was assessed using the area under the receiver operating characteristic curve (AUC). Three different criteria targeting 95% sensitivity, 95% specificity, and the maximum Youden's index, respectively, for diagnosing moderate-to-severe HS, were developed and validated. Results: The performance of deep learning-based measurements did not differ significantly, with or without radiologists' corrections (p = 0.13). Liver–spleen attenuation difference outperformed liver attenuation alone in diagnosing moderate-to-severe HS in both deep learning-based (AUC, 0.868 vs. 0.821; p = 0.001) and manual (AUC, 0.871 vs. 0.823; p = 0.001) measurements. In the test cohort, the criterion targeting 95% sensitivity for diagnosing moderate-to-severe HS (liver–spleen attenuation difference ≤ 2.8 HU) yielded 92.0% (69/75) sensitivity and 48.5% (403/831) specificity. The criterion targeting 95% specificity (liver–spleen attenuation difference ≤ -18.8 HU) yielded 53.3% (40/75) sensitivity and 95.7% (795/831) specificity. The criterion targeting the maximum Youden's index (liver–spleen attenuation difference ≤ -8.2 HU) yielded 82.7% (62/75) sensitivity and 80.7% (671/831) specificity. Conclusion: Deep learning-based automated measurements of liver and spleen attenuation on CECT can be used reliably to detect moderate-to-severe HS.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N