Accuracy and Reproducibility of Semidigital Versus Fully Digital Cephalometric Tracings Using a New Computer Program Versus Conventional Methods (Gold Standards): A Preliminary Study.

Introduction: Cephalometric tracing can be done either conventionally or using computers. Digital dentistry and digital orthodontics have considerably facilitated procedures. Still, their diagnostic accuracy needs assessment. Many orthodontic programs have been developed for this purpose. The effica...

Full description

Bibliographic Details
Published in:BioMed Research International Vol. 2025; pp. 1 - 15
Main Authors: Sobouti, Farhad, Dadgar, Sepideh, Namadian, Sina, Bahrami Rad, Hamid Reza, Rakhshan, Vahid, Banerjee, Baisakhi
Format: research tables/charts Journal Article
Published: Wiley-Blackwell 8/18/2025
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=187432761&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 187432761
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        23146133
        FT2T
      jtl: BioMed Research International
      issn: 23146133
      maglogo: N
    pubinfo:
      dt: 8/18/2025
      vid: 2025
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        187432761
        187432761
        187432761
        10.1155/bmri/8403357
        187432761
      ppf: 1
      ppct: 14
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: C
          – @attributes:
              type: P
      tig:
        atl: Accuracy and Reproducibility of Semidigital Versus Fully Digital Cephalometric Tracings Using a New Computer Program Versus Conventional Methods (Gold Standards): A Preliminary Study.
      aug:
        au:
          Sobouti, Farhad
          Dadgar, Sepideh
          Namadian, Sina
          Bahrami Rad, Hamid Reza
          Rakhshan, Vahid
          Banerjee, Baisakhi
        affil: Orthodontic Department,, Faculty of Dentistry,, Mazandaran University of Medical Sciences,, Sari, Iran, mazums.ac.ir
      sug:
        subj:
          Cephalometry
          Orthodontics
          Imaging, Three-Dimensional
          Reproducibility of Results
          Software
          Human
          Exploratory Research
          Experimental Studies
          Pilot Studies
          Observer Bias
          Image Processing, Computer Assisted
          Intraclass Correlation Coefficient
          T-Tests
          Informatics
          Radiography, Dental, Digital
          Radiographic Image Interpretation, Computer-Assisted
          Sensitivity and Specificity
          Dentistry, Operative
          Data Analysis Software
          Descriptive Statistics
      ab: Introduction: Cephalometric tracing can be done either conventionally or using computers. Digital dentistry and digital orthodontics have considerably facilitated procedures. Still, their diagnostic accuracy needs assessment. Many orthodontic programs have been developed for this purpose. The efficacy and reliability of such software are usually compared with the conventional method (gold standard). We used novel and more stringent methods of assessment to test a program in this regard. Methods: This study was performed on 10,302 tracing evaluations within 101 cases. Lateral cephalograms of 101 patients were landmarked using two methods (on paper vs. on a computer screen) and traced using three methods (completely conventionally [gold standard]; landmarks were identified on paper, but measurements were calculated by computer; landmarks were identified on the computer screen, and measurements were calculated by the computer program). A total of 15 landmarks and 17 cephalometric tracing measurements were determined via the abovementioned methods. The tracing errors were defined as differences between each pair of tracing methods, as well their absolute values (a total of 6 different tracing errors). Intraclass correlations were calculated for tracing values. Tracing errors were compared with the value 2, as the clinically acceptable range. However, they were also compared with the values zero as well as one hundredth of the mean of gold standard (as a more conservative value), using a one‐sample t‐test (α = 0.05). Results: All tracing errors were smaller than the clinically acceptable limits. Moreover, most simple errors were close to zero, and/or below the criterion of 1/100 of the mean of the gold standard. Furthermore, the more difficult error tests, that is, the directionless absolute errors, were all below 2; additionally, they were either below the 1/100 of absolute of the gold standard means or at the level of those means. Finally, the intraobserver reliabilities were high. All the 102 simple errors and absolute errors (on 101 lateral cephalograms) were significantly below 2 (p < 0.0005, clinically acceptable). Conclusions: The accuracy was appropriate. Of the 51 simple tracing errors, only 9 were significantly greater than zero, and many of them were below or at the level of 1/100 of the gold standard means. All the directionless (absolute) errors were significantly greater than zero. However, in the case of those calculated as "absolute value of (gold standard subtracted by fully digital method)," all errors were below or at the level of 1/100 of the absolute of gold standards' means. The intraobserver reliabilities were high.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N