Comparative evaluation of the cyclic fatigue resistance of four Ni-Ti instruments in simulated root canal curvatures using CAD/CAM technology.

Background: This study aimed to evaluate and compare the cyclic fatigue resistance of new generation nickel-titanium file systems in simulated single and double curvature ceramic root canals. Methods: A total of 80 Nickel–Titanium (Ni-Ti) instruments—TruNatomy (TN) (26/0.04), WaveOne Gold (WOG) (25/...

Descripción completa

Detalles Bibliográficos
Publicado en:BMC Oral Health Vol. 25; no. 1; pp. 1 - 11
Autores principales: Yıldız, Tuğçenur, Zan, Recai
Formato: pictorial research tables/charts Journal Article
Publicado: BioMed Central 8/23/2025
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=187496525&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 187496525
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        14726831
        1CIC
      jtl: BMC Oral Health
      issn: 14726831
      maglogo: N
    pubinfo:
      dt: 8/23/2025
      vid: 25
      iid: 1
      pid: 24147
      pub: BioMed Central
    artinfo:
      ui:
        187496525
        187496525
        187496525
        10.1186/s12903-025-06710-y
        187496525
      ppf: 1
      ppct: 10
      formats:
      tig:
        atl: Comparative evaluation of the cyclic fatigue resistance of four Ni-Ti instruments in simulated root canal curvatures using CAD/CAM technology.
      aug:
        au:
          Yıldız, Tuğçenur
          Zan, Recai
        affil: https://ror.org/04ttnw109 Department of Endodontics, Faculty of Dentistry, Sakarya University, 54100, Sakarya, Turkey
      sug:
        subj:
          Computer-Aided Design Utilization
          Nickel
          Titanium
          Dental Instruments
          Root Canal Therapy
          Dental Pulp Cavity
          Human
          Comparative Studies
          Turkiye
          Dentistry
          Equipment Design
          Equipment Failure
          Microscopy, Electron, Scanning
          Materials Testing
          Kruskal-Wallis Test
          Mann-Whitney U Test
          Descriptive Statistics
          Funding Source
      ab: Background: This study aimed to evaluate and compare the cyclic fatigue resistance of new generation nickel-titanium file systems in simulated single and double curvature ceramic root canals. Methods: A total of 80 Nickel–Titanium (Ni-Ti) instruments—TruNatomy (TN) (26/0.04), WaveOne Gold (WOG) (25/0.07), Reciproc Blue (RecB) (25/0.08), and One Curve (OC) (25/0.04)—were tested under simulated intracanal thermal conditions (35 ± 0.1 °C). The instruments were evaluated within custom-designed artificial canals fabricated from ceramic blocks, incorporating either a single curvature (SC; 60° angle, 5 mm radius) or a double curvature configuration (DC; coronal bend: 60°, 5 mm radius; apical bend: 60°, 2 mm radius). For each instrument, the time until fracture occurred was recorded, and the number of cycles to failure (NCF) was calculated accordingly. Fragment lengths (FLs) were measured using a digital microcaliper, and the topography of the fracture surfaces was analyzed through scanning electron microscopy (SEM). Data were statistically assessed using non-parametric Kruskal–Wallis and Mann–Whitney U tests, with significance defined at the p-value threshold of < 0.05. Results: RecB files demonstrated the highest NCF in the SC group (p < 0.05). TN and OC had significantly lower NCF than RecB (p < 0.05) but were statistically similar (p > 0.05). WOG recorded the lowest NCF in SC (p < 0.05). In the DC group, WOG also showed the lowest NCF (p < 0.05), with no significant differences among the other three files (p > 0.05). SEM analysis revealed that nearly all fractured instruments exhibited a ductile fracture pattern, characterized by the presence of microcavities and pits, which are typically associated with cyclic fatigue failure. Conclusions: Selecting Ni-Ti file systems based on canal anatomy is essential for minimizing fatigue-related failures. RecB exhibited superior resistance in SC canals, while WOG showed consistently lower performance in both configurations, warranting cautious use in curved canals. These findings underscore the importance of matching instrument selection to canal morphology and mechanical demands to ensure safe and predictable clinical outcomes.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N