Protocol for Safety, Feasibility, and Efficacy of Using Targeted Transcutaneous Spinal Cord Stimulation to Treat Hypotension During Acute Inpatient Rehabilitation in Individuals With SCI.

Transcutaneous spinal cord stimulation (tSCS) has shown evidence of leveraging intact neural circuits to increase blood pressure (BP) in hypotensive people with chronic spinal cord injury (SCI). The primary aim is to determine the safety and feasibility of using tSCS to promote seated systolic BP (S...

Descripción completa

Detalles Bibliográficos
Publicado en:Topics in Spinal Cord Injury Rehabilitation Vol. 32; no. 1; pp. 12 - 21
Autores principales: Chavez, Jorge, Curtis, Genevieve L., Weir, Joseph P., Tsai, Chung-Ying, Fox, Finn E., Harel, Noam Y., Murray, Lynda M., Goldsmith, Jacob A., Sutor, Thomas W., Huang, Vincent, Escalon, Miguel X., Bryce, Thomas N., Wecht, Jill M.
Formato: protocol tables/charts Journal Article
Publicado: KnowledgeWorks Global, Ltd Winter2026
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=191766934&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 191766934
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10820744
        0OF
      jtl: Topics in Spinal Cord Injury Rehabilitation
      issn: 10820744
      maglogo: N
    pubinfo:
      dt: Winter2026
      vid: 32
      iid: 1
      pid: 81084
      pub: KnowledgeWorks Global, Ltd
      place: Richmond, Virginia
    artinfo:
      ui:
        191766934
        191766934
        191766934
        10.46292/sci25-00028
        191766934
      ppf: 12
      ppct: 9
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Protocol for Safety, Feasibility, and Efficacy of Using Targeted Transcutaneous Spinal Cord Stimulation to Treat Hypotension During Acute Inpatient Rehabilitation in Individuals With SCI.
      aug:
        au:
          Chavez, Jorge
          Curtis, Genevieve L.
          Weir, Joseph P.
          Tsai, Chung-Ying
          Fox, Finn E.
          Harel, Noam Y.
          Murray, Lynda M.
          Goldsmith, Jacob A.
          Sutor, Thomas W.
          Huang, Vincent
          Escalon, Miguel X.
          Bryce, Thomas N.
          Wecht, Jill M.
        affil: Spinal Cord Damage Research Center, James J Peters VA Medical Center, Bronx, New York
      sug:
        subj:
          Hospitalization
          Spinal Cord Injuries Rehabilitation
          Hypotension, Orthostatic Therapy
          Spinal Cord Stimulation Methods
          Patient Safety Evaluation
          Treatment Outcomes
          Randomized Controlled Trials
          Prospective Studies
      ab: Transcutaneous spinal cord stimulation (tSCS) has shown evidence of leveraging intact neural circuits to increase blood pressure (BP) in hypotensive people with chronic spinal cord injury (SCI). The primary aim is to determine the safety and feasibility of using tSCS to promote seated systolic BP (SBP) within a target range of 110-130 mm Hg and to mitigate the fall in BP with transition to an upright position in hypotensive participants during acute inpatient rehabilitation (AIR) following SCI. Cathode placement on the spine will be randomized among 4 sites: T7/8, T9/10, T11/12, and L1/2. Mapping for other stimulation parameters includes waveform (monophasic, biphasic, pseudo-monophasic), frequency (30, 60, 120 Hz), use of a carrier frequency (0, 10 kHz), and stimulation amplitude (0-100 mA). Each mapping session will consist of 2 sit-up tests, one without stimulation followed by one with stimulation. During the sit-up test with stimulation, intensity will be slowly increased to 30 mA with continuous monitoring of BP, heart rate, pain, and symptoms of orthostatic hypotension (OH) and autonomic dysreflexia (AD). Once 30 mA is reached, brachial BP will be monitored for 5 minutes. If below the target SBP range, stimulation intensity will be increased in increments of 5 to 10 mA until one of the following occurs: (1) SBP is within the target range, (2) stimulation is intolerable, (3) 100 mA is reached, or (4) stimulation is delivered for 30 minutes. Safety and feasibility will be measured by assessing burn frequency, pain level, and symptoms of AD and OH along with scheduling compliance.
      pubtype: Academic Journal
      doctype:
        protocol
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N