Correlation between a motion analysis method and Global Operative Assessment of Laparoscopic Skills for assessing interns' performance in a simulated peg transfer task in Jordan: a validation study.

Purpose: This study aims to validate the use of ProAnalyst (Xcitex Inc.), a software for professional motion analysts to assess the performance of surgical interns while performing the peg transfer task in a simulator box for safe practice in real minimally invasive surgery. Methods: A correlation s...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Educational Evaluation for Health Professions Vol. 22; pp. 1 - 9
Autores principales: Abdelall, Esraa Saleh, Hamouri, Shadi Mohammad, Al Dwairi, Abdallah Fawaz, Al-Araidah, Omar Mefleh
Formato: pictorial research tables/charts Journal Article
Publicado: National Health Personnel Licensing Examination Board 2025
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=192170945&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 192170945
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        19755937
        B0CC
      jtl: Journal of Educational Evaluation for Health Professions
      issn: 19755937
      maglogo: N
    pubinfo:
      dt: 2025
      vid: 22
      pid: 58691
      pub: National Health Personnel Licensing Examination Board
    artinfo:
      ui:
        192170945
        192170945
        192170945
        10.3352/jeehp.2025.22.10
        192170945
      ppf: 1
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Correlation between a motion analysis method and Global Operative Assessment of Laparoscopic Skills for assessing interns' performance in a simulated peg transfer task in Jordan: a validation study.
      aug:
        au:
          Abdelall, Esraa Saleh
          Hamouri, Shadi Mohammad
          Al Dwairi, Abdallah Fawaz
          Al-Araidah, Omar Mefleh
        affil: Industrial Engineering Department, Jordan University of Science and Technology, Irbid, Jordan
      sug:
        subj:
          Motion Analysis Systems
          Interns and Residents Education
          Competency Assessment
          Clinical Competence Evaluation
          Surgery, Laparoscopic Education
          Simulations
          Task Performance and Analysis
          Minimally Invasive Procedures Education
          Patient Safety
          Software
          Human
          Validation Studies
          Jordan
          Correlational Studies
          Academic Medical Centers
          Scales
          Funding Source
          Professional Autonomy
          Interrater Reliability
          Spearman's Rank Correlation Coefficient
          Descriptive Statistics
          Data Analysis Software
          Quantitative Studies
          Internship and Residency
          Surgeons
          Comparative Studies
          Benchmarking
          Male
          Female
          Adult
          Videorecording
          Education, Medical
          Adult: 19-44 years
          Male
          Female
      ab: Purpose: This study aims to validate the use of ProAnalyst (Xcitex Inc.), a software for professional motion analysts to assess the performance of surgical interns while performing the peg transfer task in a simulator box for safe practice in real minimally invasive surgery. Methods: A correlation study was conducted in a multidisciplinary skills simulation lab at the Faculty of Medicine, Jordan University of Science and Technology from October 2019 to February 2020. Forty-one interns (i.e., novices and intermediates) were recruited and an expert surgeon participated as a reference benchmark. Videos of participants' performance were analyzed through the ProAnalyst and Global Operative Assessment of Laparoscopic Skills (GOALS). Two results were s analyzed for correlation. Results: The motion analysis scores by Proanalyst were correlated with those by GOALS for novices (r= -0.62925, P=0.009), and Intermediates (r= -0.53422, P=0.033). Both assessment methods differentiated the participants' performance based on their experience level. Conclusion: The motion analysis scoring method with Proanalyst provides an objective, time-efficient, and reproducible assessment of interns' performance, and comparable to GOALS. It may require initial training and set-up; however, it eliminates the need for expert surgeon judgment.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N