Force--time characteristics of hip high velocity, low amplitude manipulation in asymptomatic adults: with and without a drop piece.

of HVLA hip manipulation (HVLA-HM) with (DP) and without (NDP) a drop-piece. Methods: Twenty asymptomatic participants (22- 28 years; 60% female) received 3 whip HVLA-HM (DP) on one hip and 3 whip HVLA-HM (NDP) on the other. Force-time characteristics were collected using Force-Sensing Table Technol...

Full description

Bibliographic Details
Published in:Journal of the Canadian Chiropractic Association Vol. 70; no. 1; pp. 55 - 68
Main Authors: Kazemi, Mohsen, Maheswaran, Shivarny, Choi, Grand, Yip, Alison, Ferns, Heather, Harris, Glen, Funabashi, Martha
Format: pictorial research tables/charts tracings Journal Article
Published: Canadian Chiropractic Association Apr2026
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=194260794&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 194260794
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00083194
        7ZI
      jtl: Journal of the Canadian Chiropractic Association
      issn: 00083194
      maglogo: N
    pubinfo:
      dt: Apr2026
      vid: 70
      iid: 1
      pid: 8889
      pub: Canadian Chiropractic Association
      place: Toronto, Ontario
    artinfo:
      ui:
        194260794
        194260794
        194260794
        194260794
      ppf: 55
      ppct: 13
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Force--time characteristics of hip high velocity, low amplitude manipulation in asymptomatic adults: with and without a drop piece.
      aug:
        au:
          Kazemi, Mohsen
          Maheswaran, Shivarny
          Choi, Grand
          Yip, Alison
          Ferns, Heather
          Harris, Glen
          Funabashi, Martha
        affil: Canadian Memorial Chiropractic College, Division of Academics, Graduate Studies and Research, Toronto, ON
      sug:
        subj:
          Hip Joint Physiology
          Manipulation, Chiropractic Methods
          Manipulation, Chiropractic Equipment and Supplies
          Biomechanics Evaluation
          Human
          Female
          Male
          Adult
          Descriptive Research
          Nonexperimental Studies
          Cross Sectional Studies
          Students, Chiropractic
          Body Weight
          Task Performance and Analysis
          Lower Extremity Physiology
          Data Analysis Software
          Descriptive Statistics
          Confidence Intervals
          Adult: 19-44 years
          Female
          Male
      ab:
        of HVLA hip manipulation (HVLA-HM) with (DP) and without (NDP) a drop-piece. Methods: Twenty asymptomatic participants (22- 28 years; 60% female) received 3 whip HVLA-HM (DP) on one hip and 3 whip HVLA-HM (NDP) on the other. Force-time characteristics were collected using Force-Sensing Table Technology (FSTT®) and analyzed descriptively. Results: On average, HVLA-HM (DP) had a 1st peak force initiation of 40N (±19), peak force of 637N (±218), time to 1st peak of 62ms (±26), loading rate of 10763N/s (±5042) and 2nd peak force of 197N (±85). HVLA-HM (NDP) had a 1st peak force initiation of 36N (±23), peak force of 567N (±290), time to 1st peak of 63ms (±22), loading rate of 9465N/s (±5966) and 2nd peak force of 197N (±82). Conclusion: Forces during these techniques present with slightly higher peak forces and loading rates during HVLA-HM (DP) at the patient-table interface.
        Objectifs: Décrire les caractéristiques de la force et du temps de la manipulation de la hanche à haute vélocité et à faible amplitude (MH-HVLA) avec (PV) et sans (SPV) planche de vitesse. Méthodes: Vingt participants asymptomatiques (22 à 28 ans; 60 % de femmes) ont reçu trois HVLA-MH en coup de fouet (PV) sur une hanche et trois HVLA-MHen coup de fouet (SPV) sur l'autre. Les caractéristiques de la force et du temps ont été recueillies à l'aide de la technologie des tables détectant la force (FSTT®) et analysées de manière descriptive. Résultats: En moyenne, la HVLA-MH (PV) avait une première force maximale au départ de 40 N (environ 19), une force maximale de 637 N (environ 218), un temps de première force maximale de 62 ms (environ 26), un taux de charge de 10 763 N/s (environ 5042) et une deuxième force maximale de 197 N (environ 85). La HVLA-MH (SPV) avait une première force maximale au départ de 36 N (environ 23), une force maximale de 567 N (environ 290), un temps de première force maximale de 63 ms (environ 22), un taux de charge de 9465 N/s (environ 5966) et une deuxième force maximale de 197 N (environ 82). Conclusion: Les forces lors de ces techniques présentent des forces maximales et des taux de charge légèrement plus élevés pendant la HVLA-MH (DP) dans le contexte d'un patient sur une planche.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        tracings
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N