Evaluation of three mechanical chest compression devices: a simulation-based mannequin study.
Introduction: High-quality chest compressions are essential when treating out-of-hospital cardiac arrest (OHCA) patients but they may be compromised due to rescuer fatigue. Therefore, mechanical chest compression devices (MCCDS) are used, but the choice of device is a matter of debate. This study ai...
| Publicado en: | British Paramedic Journal Vol. 11; no. 1; pp. 5 - 17 |
|---|---|
| Autores principales: | , , , , , , , |
| Formato: | research tables/charts Journal Article |
| Publicado: |
College of Paramedics
Jun2026
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=194277603&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 194277603 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 14784726 LFLE jtl: British Paramedic Journal issn: 14784726 maglogo: N pubinfo: dt: Jun2026 vid: 11 iid: 1 pid: 46865 pub: College of Paramedics artinfo: ui: 194277603 194277603 194277603 10.29045/14784726.2026.6.11.1.5 194277603 ppf: 5 ppct: 12 formats: fmt: @attributes: type: P tig: atl: Evaluation of three mechanical chest compression devices: a simulation-based mannequin study. aug: au: Kjeldsen, Mads Pedersen, Rune Burholt, Peter Brian Madsen Hald, Niels Ole Saaby Bruun, Niels Henrik Rasmussen, Bodil Steen Gram, Jannie Kristine Bang Klitgaard, Thomas Lass affil: Aalborg University, Denmark sug: subj: Simulations Resuscitation, Cardiopulmonary Equipment and Supplies Equipment Reliability Evaluation Heart Arrest Therapy Prehospital Care Human Funding Source Usability Study Prospective Studies Models, Anatomic Ambulances Movement Questionnaires Paramedics Transportation of Patients Attitude of Health Personnel Descriptive Statistics Post Hoc Analysis Adult Middle Age One-Way Analysis of Variance Kruskal-Wallis Test Data Analysis Software Scales Adult: 19-44 years Middle Aged: 45-64 years ab: Introduction: High-quality chest compressions are essential when treating out-of-hospital cardiac arrest (OHCA) patients but they may be compromised due to rescuer fatigue. Therefore, mechanical chest compression devices (MCCDS) are used, but the choice of device is a matter of debate. This study aimed to compare the quality of chest compressions along with usability of three commercially available devices. Methods: The study was prospectively designed and tested LUCAS 3, AutoPulse and Corpuls CPR on the AmbuMan Advanced simulation mannequin in four different scenarios, including mounting of device, patient transport via stairs and ambulance and re-packing. The quality of chest compressions was evaluated according to current guidelines, movement of the device and usability, through a predefined questionnaire. Results: In total, 45 paramedics and 40 pre-hospital clinicians were invited to participate in the study; nine paramedics took part. A significant difference in time regarding patient transport via stairs and re-packing was observed between the tested devices. Significant differences in ratings of MCCDs regarding unpacking, mounting and the start of mechanical chest compressions, as well as overall usability of and satisfaction with the devices, were observed. LUCAS 3 and Corpuls CPR had significantly higher mean proportions of compressions within the European Resuscitation Council's recommendations as compared to AutoPulse (post-hoc analysis). Most participants recommended Corpuls CPR for future use. Conclusion: In this simulation study of OHCA attended by paramedics using mechanical chest compressions on a mannequin, the LUCAS 3 and Corpuls CPR systems were overall superior to the AutoPulse system regarding quality of chest compressions during cardiac arrest as compared to current guidelines and usability. No ultimate distinction between LUCAS 3 and Corpuls CPR could be made. pubtype: Academic Journal doctype: research tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|