Improved Suction Efficiency and User Satisfaction With a Novel Portable Manual Suction Device: A Simulation-Based Pre-Hospital Study.

Introduction: Effective airway suction is critical in prehospital care, yet many portable devices still provide limited suction performance and are poorly designed ergonomically. This study developed and evaluated a portable manual suction device intended to improve both operational performance and...

Descripción completa

Detalles Bibliográficos
Publicado en:Inquiry (00469580) Vol. 63; pp. 1 - 17
Autores principales: Saeedi, Esmail, Dorri, Safoura, Aboutalebi, Mohammad Sadegh, Ghadami, Ahmad, Heidari, Farhad
Formato: pictorial research tables/charts Journal Article
Publicado: Sage Publications Inc. 8/19/2026
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=196343853&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 196343853
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00469580
        INQ
      jtl: Inquiry (00469580)
      issn: 00469580
      maglogo: Y
    pubinfo:
      dt: 8/19/2026
      vid: 63
      pid: 344
      pub: Sage Publications Inc.
      place: Thousand Oaks, California
    artinfo:
      ui:
        196343853
        196343853
        196343853
        10.1177/00469580261468775
        196343853
      ppf: 1
      ppct: 16
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Improved Suction Efficiency and User Satisfaction With a Novel Portable Manual Suction Device: A Simulation-Based Pre-Hospital Study.
      aug:
        au:
          Saeedi, Esmail
          Dorri, Safoura
          Aboutalebi, Mohammad Sadegh
          Ghadami, Ahmad
          Heidari, Farhad
        affil: Department of Critical Care Nursing, School of Nursing and Midwifery, Isfahan University of Medical Sciences, Isfahan, Iran
      sug:
        subj:
          Suction Equipment and Supplies
          Portable Equipment
          Treatment Outcomes
          Airway Management Equipment and Supplies
          Equipment Design Evaluation
          Prehospital Care
          Quality Improvement
          Human
          Male
          Female
          Adult
          Simulations
          Laboratories
          Data Analysis Software
          Descriptive Statistics
          Emergency Medical Technicians
          Job Performance
          Convenience Sample
          Questionnaires
          Scales
          Ergonomics
          Mann-Whitney U Test
          Chi Square Test
          Funding Source
          Adult: 19-44 years
          Male
          Female
      ab: Introduction: Effective airway suction is critical in prehospital care, yet many portable devices still provide limited suction performance and are poorly designed ergonomically. This study developed and evaluated a portable manual suction device intended to improve both operational performance and operator usability during simulated airway management. Methods: In this simulation-based developmental study, all suction trials were conducted in a controlled laboratory setting using standardized simulated airway fluids and predefined environmental conditions. Suction performance was assessed using three standardized fluids. Performance outcomes included suction time, aspirated volume, and calculated efficiency. User satisfaction was measured using a validated scale ranging from 10 to 50 points. All analyses were performed using SPSS v24.0. Results: The prototype suction device demonstrated significantly shorter suction times and greater aspirated volumes across all fluid types (all p < 0.001), with efficiency gains ranging from 20% to 35%. User satisfaction and ergonomic ratings were also significantly higher with the prototype device (p < 0.001). Conclusion: The prototype suction device demonstrated superior mechanical performance and improved operator usability under simulated prehospital conditions. Its ergonomic design, integrated lighting, and disposable components collectively contributed to enhanced overall functionality. Further clinical studies are required to determine its impact in real-world prehospital settings.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N