Impacts of Biological Additives, Part 1: Solids Accumulation in Septic Tanks.

The efficacy of three septic tank additives and a control was assessed using a randomized complete-block design in a double-blind study described in this article. Sludge depth, scum thickness, and total solids were measured within 48 full-scale, functioning septic tanks. These tanks were distributed...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Environmental Health Vol. 74; no. 5; pp. 16 - 22
Autores principales: Pradhan, S., Hoover, Michael T., Clark, G. H., Gumpertz, M., Cobb, C., Strock, J.
Formato: CEU research tables/charts Journal Article
Publicado: National Environmental Health Association Dec2011
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=67471505&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 67471505
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00220892
        EVH
      jtl: Journal of Environmental Health
      issn: 00220892
      maglogo: N
    pubinfo:
      dt: Dec2011
      vid: 74
      iid: 5
      pid: 1160
      pub: National Environmental Health Association
      place: Denver, Colorado
    artinfo:
      ui:
        67471505
        67471505
        104605387
        67471505
      ppf: 16
      ppct: 6
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Impacts of Biological Additives, Part 1: Solids Accumulation in Septic Tanks.
      aug:
        au:
          Pradhan, S.
          Hoover, Michael T.
          Clark, G. H.
          Gumpertz, M.
          Cobb, C.
          Strock, J.
        affil: Professor, Department of Soil Science, North Carolina State University, P.O. Box 7619, Raleigh, NC 27695-7619
      sug:
        subj:
          Sewage Analysis
          Human
          Education, Continuing (Credit)
          Double-Blind Studies
          Descriptive Statistics
          Analysis of Variance
          Confidence Intervals
          P-Value
      ab: The efficacy of three septic tank additives and a control was assessed using a randomized complete-block design in a double-blind study described in this article. Sludge depth, scum thickness, and total solids were measured within 48 full-scale, functioning septic tanks. These tanks were distributed across three sites with low, intermediate, and high prior-maintenance levels. No significant, positive long-term additive treatment effects occurred across all maintenance levels at the α = .05 level. Separate analyses of variance, however, indicated that at the high prior-maintenance site, significant treatment effects occurred on sludge depth, scum thickness, and total solids. Sludge depths for the Liquid-Plumr and Rid-X additives were significantly reduced compared to the control at the high-maintenance site, but not at the low-maintenance site. Liquid-Plumr septic tank additive had significantly greater sludge depth at the intermediate-maintenance site, which is a negative impact. Sludge accumulation rates averaged 6.9 cm/yr. for 3,780-L (1,000 gallons) septic tanks.
      pubtype: Academic Journal
      doctype:
        CEU
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N