The Baltimore Therapeutic Equipment Work Simulator: Biomechanical and Physiological Norms for Three Attachments in Healthy Men.

Objectives. The Baltimore Therapeutic Equipment (BTE) work simulator is routinely used by occupational therapists in functional capacity evaluation. Currently, there is a lack of normative data for various attachments on this instrument. The purposes of this study were to (a) establish norms for the...

Descripción completa

Detalles Bibliográficos
Publicado en:American Journal of Occupational Therapy Vol. 48; no. 1; pp. 19 - 26
Autores principales: Bhambhani, Y., Esmail, S., Brintnell, S.
Formato: research tables/charts Journal Article
Publicado: American Occupational Therapy Association Jan1994
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=85997802&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 85997802
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        02729490
        44I
      jtl: American Journal of Occupational Therapy
      issn: 02729490
      maglogo: N
    pubinfo:
      dt: Jan1994
      vid: 48
      iid: 1
      pid: 6680
      pub: American Occupational Therapy Association
      place: North Bethesda, Maryland
    artinfo:
      ui:
        85997802
        85997802
        108008378
        10.5014/ajot.48.1.19
        85997802
      ppf: 19
      ppct: 7
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: The Baltimore Therapeutic Equipment Work Simulator: Biomechanical and Physiological Norms for Three Attachments in Healthy Men.
      aug:
        au:
          Bhambhani, Y.
          Esmail, S.
          Brintnell, S.
        affil: Associate Professor, Occupational Performance Analysis Unit, Department of Occupational Therapy. Room 373, Corbett Hall, University of Alberta, Edmonton, Canada T6G 2G4
      sug:
        subj:
          Men's Health
          Instrument Validation
          Functional Assessment
          Simulations
          Task Performance and Analysis
          Human
          Alberta
          Funding Source
          Clinical Assessment Tools
          Occupational Health
          Ergometry
          Analysis of Variance
          Male
          Young Adult
          Adult
          Scales
          Descriptive Statistics
          Post Hoc Analysis
          Data Analysis Software
          Adult: 19-44 years
          Male
      ab: Objectives. The Baltimore Therapeutic Equipment (BTE) work simulator is routinely used by occupational therapists in functional capacity evaluation. Currently, there is a lack of normative data for various attachments on this instrument. The purposes of this study were to (a) establish norms for the biomechanical and physiological responses during three tasks on the BTE work simulator, namely, wheel-turn, push-pull, and overhead-reach; (b) compare these responses during the three tasks, and (c) examine the interrelationships of these responses during the tasks. Method. Twenty healthy men completed five testing sessions: (a) task familiarization on the BTE work simulator to identify the work intensity, which was perceived as hard on the Borg scale; (b) an incremental arm ergometer exercise test to determine their peak oxygen uptake (pV02) and peak heart rate (pHR); and (c) one of the three tasks on the BTE work simulator for 4 min in each of the next three sessions. Results. Analysis of variance indicated that torque, work, and power during the overhead-reach were significantly higher (p = .000) compared with the wheel-turn and push-pull tasks. However, no significant differences (p > .05) were observed among the tasks for the VO2 and HR, which were approximately 50% and 70% of pVO2 and pHR respectively. Although there was a significant relationship (p < .05) among tasks for the torque, work, and power, the common variance ranged only between 38% and 67%. The relative pVO2 was significantly related to work (p = .028) and power (p = .027) only during the push-pull task but not the wheel-turn and overhead-reach tasks. Conclusions. These results suggest that occupational therapists should include as many tasks as possible when designing functional capacity evaluation test batteries, and that there is no consistent relationship between cardiorespiratory fitness and performance of various tasks on the BTE work simulator.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N