Single channel abdominal ECG algorithm for real-time maternal and fetal heart rate monitoring.

From a single channel abdominal ECG, a maternal (MHR) and fetal heart rate (FHR) detection method is proposed. This method is based on sequential processing: detection and cancellation of maternal QRS complexes, followed by fetal QRS complexes detection, involving hardware suitable processing techni...

Descripción completa

Detalles Bibliográficos
Publicado en:Revista Mexicana de Ingeniería Biomédica Vol. 31; no. 2; pp. 111 - 119
Autores principales: Arias-Ortega, R., Gaitán-González, M. J.
Formato: Artículo
Publicado: Sociedad Mexicana de Ingenieria Biomedica, A.C. dic2010
Materias:
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=88950399&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 88950399
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        01889532
        7L3
      jtl: Revista Mexicana de Ingeniería Biomédica
      issn: 01889532
      maglogo: N
    pubinfo:
      dt: dic2010
      vid: 31
      iid: 2
      pid: 20850
      pub: Sociedad Mexicana de Ingenieria Biomedica, A.C.
    artinfo:
      ui: 88950399
      ppf: 111
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
            size: 245KB
      tig:
        atl: Single channel abdominal ECG algorithm for real-time maternal and fetal heart rate monitoring.
      aug:
        au:
          Arias-Ortega, R.
          Gaitán-González, M. J.
        affil:
          Postgrado de Ing. Biomédica. Depto. de Ing. Eléctrica, UAM-Iztapalapa
          Depto. de Ciencias de la salud, UAM-Iztapalapa
      su:
        Electrocardiography
        Fetal heart rate monitoring
        Sequential processing (Computer science)
        Gestational age
        Pregnant women
        Cohen's kappa coefficient (Statistics)
        Analysis of variance
      sug:
        subj:
          Electrocardiography
          Fetal heart rate monitoring
          Sequential processing (Computer science)
          Gestational age
          Pregnant women
          Cohen's kappa coefficient (Statistics)
          Analysis of variance
      keyword:
        Abdominal ECG
        fetal heart rate
        maternal heart rate
        portable device
        real time processing
        ECG Abdominal
        equipo portátil
        frecuencia cardiaca fetal
        procesamiento en tiempo real
      ab:
        From a single channel abdominal ECG, a maternal (MHR) and fetal heart rate (FHR) detection method is proposed. This method is based on sequential processing: detection and cancellation of maternal QRS complexes, followed by fetal QRS complexes detection, involving hardware suitable processing techniques. The algorithm was tested on a group of 25 different gestational age pregnant women signals; its performance was assessed using detections obtained by another single channel method and an expert physician. Concordance was evaluated by Cohen's kappa coefficient and sensitivity comparison was done by repeated measures ANOVA for method and gestational age (p < 0.05). Sensitivity behavior against fetal SNR was obtained as well as temporal coincidence of fetal and maternal complexes. Both methods presented similar high Cohen's kappa coefficients, with detection success rates superior to 97% and 88% for maternal and fetal complexes respectively, but for 38 weeks of pregnancy the proposed method had lower maternal success rate than reference one (90%, p > 0.05). Proposed algorithm may be implemented in an independent platform and only requires operator supervision at the beginning of the process.
        Se propone un método para la detección de la frecuencia cardiaca fetal (FCF) y materna (FCM) partiendo de un solo canal abdominal. Consiste en una serie de pasos secuenciales: detección y cancelación de los complejos QRS maternos, seguidos de la detección de los complejos QRS fetales, involucrando técnicas de procesamiento que se pueden implementar en hardware. El método se evaluó en un conjunto de 25 registros abdominales de mujeres embarazadas con diferentes edades gestacionales. Su desempeño se comparó contra edigraphic.org.mx edigraphic.org.mx las detecciones realizadas por un experto y contra otro método de detección. El nivel de acuerdo se evaluó con el índice kappa de Cohen y la sensibilidad se comparó por análisis de varianza para muestras repetidas con métodos y edades gestacionales como factores (p < 0.05). Ambos métodos presentaron altos índices kappa, con tasas de detecciones similares, superiores al 97% y 88% para los complejos maternos y fetales respectivamente, a excepción de los registros con edades gestacionales superiores a la semana 38, donde el método propuesto presentó tasas de detecciones maternas más bajas que las de referencia (90%, p > 0.05). El algoritmo propuesto puede ser implementado en una plataforma independiente y sólo requiere de la supervisión de un operador al inicio del proceso.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: English
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Revista Mexicana de Ingeniería Biomédica is the property of Sociedad Mexicana de Ingenieria Biomedica, A.C. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Revista Mexicana de Ingeniería Biomédica
      holder: Sociedad Mexicana de Ingenieria Biomedica, A.C.
      dt:
        @attributes:
          year: 2010
    holdings:
      @attributes:
        islocal: N