Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose.

Objectives: To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR).Methods: The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 24; no. 2; pp. 460 - 469
Autores principales: Chen, Chien-Ming, Chu, Sung-Yu, Hsu, Ming-Yi, Liao, Ying-Lan, Tsai, Hui-Yu
Formato: research Journal Article
Publicado: Springer Nature Feb2014
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=104003745&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 104003745
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Feb2014
      vid: 24
      iid: 2
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        104003745
        104003745
        NLM24081645
        2012446277
        10.1007/s00330-013-3027-3
        NLM24081645
        104003745
      ppf: 460
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose.
      aug:
        au:
          Chen, Chien-Ming
          Chu, Sung-Yu
          Hsu, Ming-Yi
          Liao, Ying-Lan
          Tsai, Hui-Yu
        affil: Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital Linkou, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
      sug:
        subj:
          Angiography Methods
          Tomography, X-Ray Computed Methods
          Contrast Media Diagnostic Use
          Radiographic Image Interpretation, Computer-Assisted Methods
          Adult
          Aged
          Contrast Media Administration and Dosage
          Dose-Response Relationship, Drug
          Female
          Prospective Studies
          Human
          Male
          Middle Age
          Pilot Studies
          Radiation Dosage
          Adult: 19-44 years
          Aged: 65+ years
          Middle Aged: 45-64 years
          Female
          Male
      ab: Objectives: To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR).Methods: The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDIvol), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts.Results: The low-tube-voltage protocol showed 23-31% higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48% reduction in CTDIvol and an 80% increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01).Conclusions: Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality.Key Points: • CT aortography at 80 kVp allows a significant reduction in radiation dose. • Addition of iterative reconstruction reduces image noise and improves image quality. • The injected contrast medium dose can be substantially reduced at 80 kVp. • Aortic enhancement is uniform despite a reduced volume of contrast medium.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N