Clinically useful dilution factors for iodine and gadolinium contrast material: an animal model of pediatric digital subtraction angiography using state-of-the-art flat-panel detectors.

Background: Iodinated and gadolinium contrast agents pose some risk for certain pediatric patients, including allergic-like reactions, contrast-induced nephropathy (CIN) and nephrogenic systemic fibrosis (NSF). Digital flat-panel detectors enhance image quality during angiography and might allow use...

Descripción completa

Detalles Bibliográficos
Publicado en:Pediatric Radiology Vol. 43; no. 11; pp. 1491 - 1502
Autores principales: Racadio, John M, Kashinkunti, Soumya R, Nachabe, Rami A, Racadio, Judy M, Johnson, Neil D, Kukreja, Kamlesh U, Patel, Manish N, Privitera, Mary Beth, Hales, Jasmine E, Abruzzo, Todd A
Formato: research Journal Article
Publicado: Springer Nature Nov2013
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Background: Iodinated and gadolinium contrast agents pose some risk for certain pediatric patients, including allergic-like reactions, contrast-induced nephropathy (CIN) and nephrogenic systemic fibrosis (NSF). Digital flat-panel detectors enhance image quality during angiography and might allow use of more dilute contrast material to decrease risk of complications that might be dose-dependent, such as CIN and NSF.Objective: To assess the maximum dilution factors for iodine- and gadolinium-based contrast agents suitable for vascular imaging with fluoroscopy and digital subtraction angiography (DSA) on digital flat-panel detectors in an animal model.Materials and Methods: We performed selective catheterization of the abdominal aorta, renal artery and common carotid artery on a rabbit. In each vessel we performed fluoroscopy and DSA during contrast material injection using iodinated and gadolinium contrast material at 100%, 80%, 50%, 33% and 20% dilutions. An image quality score (0 to 3) was assigned by each of eight evaluators. Intracorrelation coefficient, paired t-test, one-way repeated analysis of variance, Spearman correlation and receiver operating characteristic curve analysis were applied to the data.Results: Overall the image quality scores correlated linearly with dilution levels. For iodinated contrast material, the optimum cut-off level for DSA when a score of at least 2 is acceptable is above 33%; it is above 50% when a score of 3 is necessary. For gadolinium contrast material, the optimum cut-off for DSA images is above 50% when a score of at least 2 is acceptable and above 80% when a score of 3 is necessary.Conclusion: Knowledge of the relationship between image quality and contrast material dilution might allow a decrease in overall contrast load while maintaining appropriate image quality when using digital flat-panel detectors.