The automatic implantable cardioverter/ defibrillator: transesophageal atrial pacing discloses the potential for erroneous discharges.

We report the occurrence of erroneous discharge from an implanted automatic cardioverter/defibrillator during transesophageal atrial pacing. Transesophageal pacing was performed as part of a study protocol on the inducibility of ventricular tachycardia from the atrium in patients with ischemic heart...

Descripción completa

Detalles Bibliográficos
Publicado en:Pacing & Clinical Electrophysiology Vol. 11; no. 4; pp. 419 - 423
Autores principales: Critelli G, Monda V, Scherillo M, Coltorti F, Greco C, Reale A
Formato: case study Journal Article
Publicado: Wiley-Blackwell Apr1988
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106087146&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106087146
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01478389
        4F8
      jtl: Pacing & Clinical Electrophysiology
      issn: 01478389
      maglogo: Y
    pubinfo:
      dt: Apr1988
      vid: 11
      iid: 4
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        106087146
        2009413483
        10.1111/j.1540-8159.1988.tb06001.x
        NLM2453037
        106087146
      ppf: 419
      ppct: 4
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: The automatic implantable cardioverter/ defibrillator: transesophageal atrial pacing discloses the potential for erroneous discharges.
      aug:
        au:
          Critelli G
          Monda V
          Scherillo M
          Coltorti F
          Greco C
          Reale A
      sug:
        subj:
          Cardiac Pacing, Artificial Methods
          Cardioversion Equipment and Supplies
          Male
          Middle Age
          Middle Aged: 45-64 years
          Male
      ab: We report the occurrence of erroneous discharge from an implanted automatic cardioverter/defibrillator during transesophageal atrial pacing. Transesophageal pacing was performed as part of a study protocol on the inducibility of ventricular tachycardia from the atrium in patients with ischemic heart disease. At on induced heart rate of 166 beats per minute (a value just above the cut-off rate of the device), the cardioverter/defibrillator was triggered. This observation suggests that transesophageal atrial pacing could be utilized to disclose the potential [or spurious discharges in the event of fast atrial rhythms in patients with the automatic implantable cardioverter/defibrillator.
      pubtype: Academic Journal
      doctype:
        case study
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N