Manual versus digital radiographic measurements in acetabular dysplasia.

The intraobserver and interobserver variability of common radiographic measurements associated with hip dysplasia from plain and digital radiographs was assessed. Only the interobserver reliability of measuring Hilgenreiner's distance was found to be potentially clinically significant. The average S...

Descripción completa

Detalles Bibliográficos
Publicado en:Orthopedics Vol. 29; no. 8; pp. 724 - 727
Autores principales: Halanski MA, Noonan KJ, Hebert M, Nemeth BA, Mann DC, Leverson G, Halanski, Mathew A, Noonan, Kenneth J, Hebert, Mathew, Nemeth, Blaise A, Mann, David C, Leverson, Glen
Formato: diagnostic images research Journal Article
Publicado: SLACK Incorporated Aug2006
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=106288460&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 106288460
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01477447
        7IT
      jtl: Orthopedics
      issn: 01477447
      maglogo: N
    pubinfo:
      dt: Aug2006
      vid: 29
      iid: 8
      pid: 1693
      pub: SLACK Incorporated
      place: Thorofare, New Jersey
    artinfo:
      ui:
        106288460
        NLM16924867
        2009256121
        10.3928/01477447-20060801-07
        NLM16924867
        106288460
      ppf: 724
      ppct: 3
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Manual versus digital radiographic measurements in acetabular dysplasia.
      aug:
        au:
          Halanski MA
          Noonan KJ
          Hebert M
          Nemeth BA
          Mann DC
          Leverson G
          Halanski, Mathew A
          Noonan, Kenneth J
          Hebert, Mathew
          Nemeth, Blaise A
          Mann, David C
          Leverson, Glen
        affil: University of Wisconsin, Dept of Orthopedics and Rehabilitation, K4/732 Clinical Science Center, 600 Highland Ave, Madison, WI 53792, USA
      sug:
        subj:
          Clinical Assessment Tools
          Data Analysis, Computer Assisted
          Hip Dislocation, Congenital Radiography
          Instrument Validation
          Radiography, Computed
          Child, Preschool
          Data Analysis Software
          Descriptive Statistics
          Image Processing, Computer Assisted
          Infant
          Interrater Reliability
          Intrarater Reliability
          Pelvis Radiography
          Random Sample
          Reproducibility of Results
          Retrospective Design
          Spearman's Rank Correlation Coefficient
          Validation Studies
          Wilcoxon Signed Rank Test
          Human
          Child, Preschool: 2-5 years
          Infant: 1-23 months
      ab: The intraobserver and interobserver variability of common radiographic measurements associated with hip dysplasia from plain and digital radiographs was assessed. Only the interobserver reliability of measuring Hilgenreiner's distance was found to be potentially clinically significant. The average Spearman correlation coefficients between groups were 0.81 acetabular index, 0.80 medial teardrop to medial metaphysis distance, and 0.77 Hilgenreiner's distance. The average difference between digital and plain radiographs was acetabular index 0.97 +/- 0.6 degrees, medial teardrop to medial metaphysis distance 0.5 +/- 0.56 mm, and Hilgenreiner's distance 0.41 +/- 0.78 mm. These values are clinically insignificant; therefore, digital radiographs are as reliable as conventional radiographs in assessing hip dysplasia.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N