Pulmonary emphysema diagnosis with a preclinical small-animal X-ray dark-field scatter-contrast scanner.

Purpose: To test the hypothesis that the joint distribution of x-ray transmission and dark-field signals obtained with a compact cone-beam preclinical scanner with a polychromatic source can be used to diagnose pulmonary emphysema in ex vivo murine lungs.Materials and Methods: The animal care commit...

Descripción completa

Detalles Bibliográficos
Publicado en:Radiology Vol. 269; no. 2; pp. 427 - 434
Autores principales: Yaroshenko, Andre, Meinel, Felix G, Bech, Martin, Tapfer, Arne, Velroyen, Astrid, Schleede, Simone, Auweter, Sigrid, Bohla, Alexander, Yildirim, Ali Ö, Nikolaou, Konstantin, Bamberg, Fabian, Eickelberg, Oliver, Reiser, Maximilian F, Pfeiffer, Franz
Formato: research Journal Article
Publicado: Wolters Kluwer Health 2013 Nov
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Purpose: To test the hypothesis that the joint distribution of x-ray transmission and dark-field signals obtained with a compact cone-beam preclinical scanner with a polychromatic source can be used to diagnose pulmonary emphysema in ex vivo murine lungs.Materials and Methods: The animal care committee approved this study. Three excised murine lungs with pulmonary emphysema and three excised murine control lungs were imaged ex vivo by using a grating-based micro-computed tomographic (CT) scanner. To evaluate the diagnostic value, the natural logarithm of relative transmission and the natural logarithm of dark-field scatter signal were plotted on a per-pixel basis on a scatterplot. Probability density function was fit to the joint distribution by using principle component analysis. An emphysema map was calculated based on the fitted probability density function.Results: The two-dimensional scatterplot showed a characteristic difference between control and emphysematous lungs. Control lungs had lower average median logarithmic transmission (-0.29 vs -0.18, P = .1) and lower average dark-field signal (-0.54 vs -0.37, P = .1) than emphysematous lungs. The angle to the vertical axis of the fitted regions also varied significantly (7.8° for control lungs vs 15.9° for emphysematous lungs). The calculated emphysema distribution map showed good agreement with histologic findings.Conclusion: X-ray dark-field scatter images of murine lungs obtained with a preclinical scanner can be used in the diagnosis of pulmonary emphysema.Supplemental Material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122413/-/DC1.