Development and Preliminary Validation of a Digital Overlay-based Learning Module for Semiquantitative Evaluation of Magnetic Resonance Imaging Lesions in Osteoarthritis of the Hip.

Objective: To develop and validate a knowledge transfer (KT) module aimed at enhancing feasibility and reliability of semiquantitative assessment of bone marrow lesions (BML) and synovitis-effusion using the Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS).Methods: Three radiolog...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Rheumatology Vol. 43; no. 1; pp. 232 - 239
Autores principales: Maksymowych, Walter P., Pitts, Meaghan, Budak, Matthew J., Gracey, David, Lambert, Robert G., McDougall, David, Pianta, Marcus, Rennie, Winston J., Wichuk, Stephanie, Winn, Naomi, Jaremko, Jacob L.
Formato: research Journal Article
Publicado: Journal of Rheumatology Publishing Co. Ltd. Jan2016
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Objective: To develop and validate a knowledge transfer (KT) module aimed at enhancing feasibility and reliability of semiquantitative assessment of bone marrow lesions (BML) and synovitis-effusion using the Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS).Methods: Three radiologists naive to the HIMRISS method reviewed the manuscript describing the method and then scored MRI scans from 16 patients with hip OA obtained at baseline and 8 weeks after intraarticular injection of corticosteroid. Readers then reviewed a KT module comprising an instructional presentation and 8 reference DICOM (digital imaging and communications in medicine) cases scored by 3 readers with expertise in the HIMRISS method, and then used electronic overlay software to score scans from 23 patients with OA. The same format was followed with a second group of 3 readers naive to HIMRISS using a KT module revised to incorporate the overlay with a Web-based DICOM viewer to enhance feasibility. Interobserver reliability was assessed with the intraclass correlation coefficient (ICC).Results: In both exercises, reliability for baseline scores was excellent for femoral BML, very good for acetabular BML, and good for synovitis-effusion (overall ICC = 0.91, 0.89, 0.62, respectively) even without prior calibration using the KT module. However, reliability for detecting change was substantially worse than for expert readers, especially for acetabular BML and synovitis-effusion (overall ICC = 0.59 vs 0.19, and 0.42 vs 0.25, respectively). Reliability improved for detection of change in these lesions, especially after reader calibration with the revised KT module.Conclusion: Development and validation of a systematic method for KT may enhance external validation of certain imaging instruments.