Development and Preliminary Validation of a Digital Overlay-based Learning Module for Semiquantitative Evaluation of Magnetic Resonance Imaging Lesions in Osteoarthritis of the Hip.

Objective: To develop and validate a knowledge transfer (KT) module aimed at enhancing feasibility and reliability of semiquantitative assessment of bone marrow lesions (BML) and synovitis-effusion using the Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS).Methods: Three radiolog...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Rheumatology Vol. 43; no. 1; pp. 232 - 239
Autores principales: Maksymowych, Walter P., Pitts, Meaghan, Budak, Matthew J., Gracey, David, Lambert, Robert G., McDougall, David, Pianta, Marcus, Rennie, Winston J., Wichuk, Stephanie, Winn, Naomi, Jaremko, Jacob L.
Formato: research Journal Article
Publicado: Journal of Rheumatology Publishing Co. Ltd. Jan2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=112443233&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 112443233
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        0315162X
        4CM
      jtl: Journal of Rheumatology
      issn: 0315162X
      maglogo: N
    pubinfo:
      dt: Jan2016
      vid: 43
      iid: 1
      pid: 6803
      pub: Journal of Rheumatology Publishing Co. Ltd.
      place: Toronto, Ontario
    artinfo:
      ui:
        112443233
        112443233
        NLM26077400
        112443233
        10.3899/jrheum.141574
        NLM26077400
        112443233
      ppf: 232
      ppct: 7
      formats:
      tig:
        atl: Development and Preliminary Validation of a Digital Overlay-based Learning Module for Semiquantitative Evaluation of Magnetic Resonance Imaging Lesions in Osteoarthritis of the Hip.
      aug:
        au:
          Maksymowych, Walter P.
          Pitts, Meaghan
          Budak, Matthew J.
          Gracey, David
          Lambert, Robert G.
          McDougall, David
          Pianta, Marcus
          Rennie, Winston J.
          Wichuk, Stephanie
          Winn, Naomi
          Jaremko, Jacob L.
        affil: FRCPC, Professor, Department of Medicine, University of Alberta
      sug:
        subj:
          Magnetic Resonance Imaging Methods
          Osteoarthritis, Hip Pathology
          Severity of Illness Indices
          Image Interpretation, Computer Assisted
          Education, Medical
          Middle Age
          Sensitivity and Specificity
          Human
          Aged
          Male
          Female
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
          Middle Aged: 45-64 years
          Aged: 65+ years
          Male
          Female
      ab: Objective: To develop and validate a knowledge transfer (KT) module aimed at enhancing feasibility and reliability of semiquantitative assessment of bone marrow lesions (BML) and synovitis-effusion using the Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS).Methods: Three radiologists naive to the HIMRISS method reviewed the manuscript describing the method and then scored MRI scans from 16 patients with hip OA obtained at baseline and 8 weeks after intraarticular injection of corticosteroid. Readers then reviewed a KT module comprising an instructional presentation and 8 reference DICOM (digital imaging and communications in medicine) cases scored by 3 readers with expertise in the HIMRISS method, and then used electronic overlay software to score scans from 23 patients with OA. The same format was followed with a second group of 3 readers naive to HIMRISS using a KT module revised to incorporate the overlay with a Web-based DICOM viewer to enhance feasibility. Interobserver reliability was assessed with the intraclass correlation coefficient (ICC).Results: In both exercises, reliability for baseline scores was excellent for femoral BML, very good for acetabular BML, and good for synovitis-effusion (overall ICC = 0.91, 0.89, 0.62, respectively) even without prior calibration using the KT module. However, reliability for detecting change was substantially worse than for expert readers, especially for acetabular BML and synovitis-effusion (overall ICC = 0.59 vs 0.19, and 0.42 vs 0.25, respectively). Reliability improved for detection of change in these lesions, especially after reader calibration with the revised KT module.Conclusion: Development and validation of a systematic method for KT may enhance external validation of certain imaging instruments.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N