A semi-automated volumetric software for segmentation and perfusion parameter quantification of brain tumors using 320-row multidetector computed tomography: a validation study.
Purpose: We developed a semi-automated volumetric software, NPerfusion, to segment brain tumors and quantify perfusion parameters on whole-brain CT perfusion (WBCTP) images. The purpose of this study was to assess the feasibility of the software and to validate its performance compared with manual s...
| Publicado en: | Neuroradiology Vol. 59; no. 5; pp. 461 - 470 |
|---|---|
| Autores principales: | , , , , , , |
| Formato: | diagnostic images research tables/charts Journal Article |
| Publicado: |
Springer Nature
May2017
|
| Acceso en línea: | Ver este registro en EBSCOhost |