On site comparison of the OSHA 42, Asset EZ4-NCO, Iso-Chek, DAN and CIP10 methods for measuring toluene diisocyanate (TDI) at a polyurethane foam factory.

Because of the semi-volatile nature of diisocyanates (being airborne in both physical vapor and particulate phases), their high reactivity and low occupational exposure limits, diisocyanate exposure evaluation has been challenging for industrial hygienists and laboratories. The objective of this stu...

Full description

Bibliographic Details
Published in:Journal of Occupational & Environmental Hygiene Vol. 17; no. 5; pp. 207 - 220
Main Authors: Aubin, Simon, Hamdi, El Mekki, Joly, Audrey, Sarazin, Philippe, Lesage, Jacques, Breau, Livain, Spence, Mark, Gagné, Sébastien
Format: pictorial research tables/charts Journal Article
Published: Taylor & Francis Ltd May2020