Compliance with design principles: a case study of a widely used laboratory information system.

Background: Laboratory information systems are widely used health information systems that have the potential to improve health care quality. Despite their benefits, many studies have indicated problems with user interaction with these systems due to poor interface design. Aims: To evaluate the usab...

Descripción completa

Detalles Bibliográficos
Publicado en:Eastern Mediterranean Health Journal Vol. 26; no. 12; pp. 1456 - 1465
Autores principales: Agharezaei, Zhila, Khajouei, Reza, Ahmadia, Leila, Agharezaei, Laleh
Formato: research tables/charts Journal Article
Publicado: World Health Organization Dec2020
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=147546275&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 147546275
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10203397
        Z0U
      jtl: Eastern Mediterranean Health Journal
      issn: 10203397
      maglogo: N
    pubinfo:
      dt: Dec2020
      vid: 26
      iid: 12
      pid: 437
      pub: World Health Organization
    artinfo:
      ui:
        147546275
        147546275
        147546275
        10.26719/emhj.20.029
        147546275
      ppf: 1456
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Compliance with design principles: a case study of a widely used laboratory information system.
      aug:
        au:
          Agharezaei, Zhila
          Khajouei, Reza
          Ahmadia, Leila
          Agharezaei, Laleh
        affil: Department of Medical Informatics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Islamic Republic of Iran
      sug:
        subj:
          Clinical Laboratory Information Systems Utilization
          Health Information Systems
          Quality of Health Care
          User-Computer Interface
          Human
          Descriptive Research
          Cross Sectional Studies
          Academic Medical Centers Iran
          Iran
          Content Analysis
          Descriptive Statistics
          Patient Admission
      ab:
        Background: Laboratory information systems are widely used health information systems that have the potential to improve health care quality. Despite their benefits, many studies have indicated problems with user interaction with these systems due to poor interface design. Aims: To evaluate the usability of a laboratory information system. Methods: In this descriptive, cross-sectional study, we used heuristic evaluation to examine the user interface design of a laboratory information system in an academic hospital affiliated with Kerman University of Medical Sciences in 2017. This system is also used in 59 other Iranian hospitals .We investigated the usability of different parts of the usability of a laboratory information system (outpatient admission, inpatient admission, sample collection, and test result reporting). Data were collected using a standard form based on the heuristic evaluation method, and categorized based on their severity and violated heuristics. The content validity was confirmed by 3 medical informatics specialists. Results: We identified 162 usability problems. In terms of the heuristics, the highest number of problems concerned flexibility and efficiency of use (n = 32, 19.75%) and the lowest concerned help users recognize, diagnose, and recover from errors (n = 2, 1.23%). In terms of different modules of the system, the highest number of problems (n = 51, 31.48%) concerned outpatient admission and the lowest (n = 29, 17.9%) concerned sample collection. In terms of severity, 45.06% of the problems were rated as major. Conclusions: Despite widespread use of laboratory information systems, their user interface design has usability problems that diminish the quality of user interaction with these systems and may affect the quality of health care. Consideration of standards and principles for user interface design, such as the heuristics used in this study, could improve system usability.
        Contexte : Les systèmes d'information de laboratoire sont des systèmes d'information sanitaire largement utilisés qui ont le potentiel d'améliorer la qualité des soins de santé. Ces systèmes présentent des avantages, mais de nombreuses études ont mis en évidence des problèmes d'interaction avec les utilisateurs en raison d'une mauvaise conception de l'interface. Objectifs : La présente étude visait à évaluer l'utilisabilité des systèmes d'information de laboratoire en milieu hospitalier. Méthodes : Dans la présente étude transversale descriptive, réalisée en 2017, nous avons eu recours à l'évaluation heuristique pour examiner la conception de l'interface utilisateur d'un système d'information de laboratoire employé dans un hôpital universitaire affilié à l'Université des Sciences médicales de Kerman. Ce système est également utilisé dans 59 autres hôpitaux iraniens. Nous avons étudié l'utilisabilité de différents modules du système (admission en ambulatoire, admission en séjour hospitalier, collecte d'échantillons et notification des résultats de test). Les données ont été recueillies à l'aide d'un formulaire type basé sur la méthode d'évaluation heuristique. Elles ont ensuite été classées selon leur gravité et les heuristiques ayant été transgressées. La validité du contenu a été confirmée par trois spécialistes en informatique médicale. Résultats : Nous avons recensé 162 problèmes d'utilisabilité. L'heuristique pour laquelle le plus grand nombre de problèmes ont été rapportés était la flexibilité et l'efficacité d'utilisation (n = 32, 19,75 %), tandis que l'aide à la reconnaissance, au diagnostic et à la réparation des erreurs était celle pour laquelle on rapportait le plus petit nombre de problèmes (n = 2, 1,23 %). L'admission ambulatoire était le module du système pour lequel le plus grand nombre de problèmes a été notifié (n = 51, 31,48 %), tandis que la collecte d'échantillons était celui pour lequel on rapportait le plus petit nombre de problèmes a été notifié (n = 29, 17,9 %). En ce qui concerne la gravité, 45,06 % des problèmes ont été jugés majeurs. Conclusions : Malgré l'utilisation répandue des systèmes d'information de laboratoire, les interfaces présentent souvent des problèmes d'utilisabilité qui diminuent la qualité de l'interaction avec les utilisateurs et peuvent affecter la qualité des soins de santé offerts. Ainsi, au moment de concevoir les interfaces utilisateurs, il pourrait être utile de s'appuyer sur des normes et des principes, à l'instar des heuristiques utilisées dans cette étude. Cela pourrait en effet permettre d'améliorer la convivialité des systèmes.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N