Anestésicos volátiles en oxigenadores durante la circulación extracorpórea.

Introduction: Continuous monitoring of exhaled concentrations and CO levels is often lacking during the administration of inhaled anesthetics in cardiopulmonary bypass (CPB), these levels often being adjusted intermittently based on blood gas values. This approach disregards variations in fresh gas...

Full description

Bibliographic Details
Published in:Colombian Journal of Anesthesiology / Revista Colombiana de Anestesiología Vol. 53; no. 3; pp. 1 - 10
Main Authors: Gutiérrez-Soriano, Laura, Kling-Gómez, Juan Carlos, Becerra-Zapata, Eduardo, Quintero, Olga, Maya-Trujillo, Nicolás, Peña-Blanco, Laura
Format: Article
Published: Sociedad Colombiana de Anestesiologia y Reanimacion Jul-Sep2025
Subjects:
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=188011055&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 188011055
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        01203347
        B54X
      jtl: Colombian Journal of Anesthesiology / Revista Colombiana de Anestesiología
      issn: 01203347
      maglogo: N
    pubinfo:
      dt: Jul-Sep2025
      vid: 53
      iid: 3
      pid: 56584
      pub: Sociedad Colombiana de Anestesiologia y Reanimacion
    artinfo:
      ui:
        188011055
        10.5554/22562087.e1150
      ppf: 1
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
            size: 996KB
      tig:
        atl: Anestésicos volátiles en oxigenadores durante la circulación extracorpórea.
      aug:
        au:
          Gutiérrez-Soriano, Laura
          Kling-Gómez, Juan Carlos
          Becerra-Zapata, Eduardo
          Quintero, Olga
          Maya-Trujillo, Nicolás
          Peña-Blanco, Laura
        affil:
          Anestesiología Cardiovascular, Fundación Cardioinfantil. Bogotá, Colombia.
          Investigación Clínica, Departamento de Anestesiología, Fundación Cardioinfantil. Bogotá, Colombia.
          Anestesiología Cardiovascular, Fundación Santa Fe. Bogotá, Colombia.
      su:
        Cardiopulmonary bypass
        Oxygenators
        Gas dynamics
        Carbon dioxide detectors
        Automatic tracking
        Cardiac surgery
        Anesthetics
      sug:
        subj:
          Cardiopulmonary bypass
          Oxygenators
          Gas dynamics
          Carbon dioxide detectors
          Automatic tracking
          Cardiac surgery
          Anesthetics
      keyword:
        Anesthesia during bypass
        Cardiopulmonary bypass monitoring
        Membrane oxygenator
        Volatile anesthetics, Real-time monitoring
        Anestésicos volátiles
        Anestesia durante la circulación extracorpórea
        Monitorización de la circulación extracorpórea
        Monitorización en tiempo real
        Oxigenador de membrana
      ab:
        Introduction: Continuous monitoring of exhaled concentrations and CO levels is often lacking during the administration of inhaled anesthetics in cardiopulmonary bypass (CPB), these levels often being adjusted intermittently based on blood gas values. This approach disregards variations in fresh gas and circulatory flows between blood samples. Objective: To assess gas behavior during bypass circulation, evaluate data reliability, and analyze gradients through the membrane oxygenator. Methods: Real-time monitoring of inhaled and exhaled volatile anesthetics, CO, and oxygen was conducted at the oxygenator inlet and outlet ports during CPB. Seventy adult patients undergoing cardiac surgery on CPB were included in order to analyze the impact of circulatory flow across different oxygenators. Results: A strong correlation was found between end-tidal CO and arterial blood gas CO (Spearman’s Rho = 0.74, p = 0.00). Isoflurane gradients differed significantly among the Affinity, Fusion, and Terumo oxygenators (p = 0.015). Equilibrium for Isoflurane was reached in 493.9 ± 164.98 seconds (95% CI: 454–532 seconds). When circulatory flow was reduced to 0.5 L/min, exhaled concentrations increased significantly (Fisher’s T, p = 0.07). Sevoflurane washout varied significantly across oxygenators at CPB initiation (mean: 117.5 s). Conclusions: Continuous monitoring of inhaled and exhaled gases during CPB should be mandatory to optimize anesthetic delivery and achieve targeted plasma concentrations.
        Introducción: La monitorización continua de las concentraciones exhaladas y los niveles de CO a menudo falta durante la administración de anestésicos inhalados en la circulación extracorpórea (CEC), niveles que se ajustan de manera intermitente basándose en los valores de gases en sangre. Este enfoque no considera las variaciones en los flujos de gas fresco y circulatorio entre las muestras de sangre. Objetivo: Evaluar el comportamiento de los gases durante la circulación extracorpórea, evaluar la fiabilidad de los datos y analizar los gradientes a través del oxigenador de membrana. Métodos: Se realizó una monitorización en tiempo real de los anestésicos volátiles inhalados y exhalados, CO y oxígeno en las entradas y salidas del oxigenador durante la CEC. Se incluyeron 70 pacientes adultos sometidos a cirugía cardiaca con CEC para analizar el impacto del flujo circulatorio en diferentes oxigenadores. Resultados: Se encontró una fuerte correlación entre el CO al final de la espiración y el CO en los gases arteriales (Rho de Spearman = 0,74, p = 0,00). Los gradientes de isoflurano difirieron significativamente entre los oxigenadores Affinity, Fusion y Terumo (p = 0,015). El equilibrio para el isoflurano se alcanzó en 493,90 ± 164,98 segundos (IC 95 %: 454-532 segundos). Cuando el flujo circulatorio se redujo a 0,5 L/min, las concentraciones exhaladas aumentaron significativamente (T de Fisher, p = 0,07). El lavado de sevoflurano varió significativamente entre los oxigenadores al inicio de la CEC (media: 117,5 s). Conclusiones: La monitorización continua de los gases inhalados y exhalados durante la CEC debería ser obligatoria para optimizar la administración de anestésicos y alcanzar las concentraciones plasmáticas deseadas.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: Spanish
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Colombian Journal of Anesthesiology / Revista Colombiana de Anestesiología is the property of Sociedad Colombiana de Anestesiologia y Reanimacion and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Colombian Journal of Anesthesiology / Revista Colombiana de Anestesiología
      holder: Sociedad Colombiana de Anestesiologia y Reanimacion
      dt:
        @attributes:
          year: 2025
    holdings:
      @attributes:
        islocal: N